Download Print this page

10. Troubleshooting - Sealey GV180WM Instructions Manual

Garage vacuum 1500w with remote control - wall mounting

Advertisement

9.4.
inStalling the Foam Sleeve Filter
9.4.1. Make sure the power cord is disconnected from the outlet. (fig.9.1).
9.4.2. Remove the power head and place upside down. Follow instructions to remove cloth filter, refer to 9.3.
9.4.3. Carefully slide foam filter down over the filter cage, making sure the whole cage is covered. (fig.9.2 & 9.3).
9.4.4. replace the power head on the container.
9.5.
cleaning the Foam Sleeve Filter
9.5.1. With the removed power head in the upside down position, carefully remove the foam filter. (fig.9.4).
9.5.2. Use mild soap and water solution to wash foam filter and rinse again with clean water. (fig.9.5).
9.5.3. Allow filter to air dry before installing and using again.
9.6.
reSetting the remote control
fig.10
9.6.1. Have the remote control accessable. Set the power switch on the vacuum to remote control position . (fig.10.1).
9.6.2. Press the rEsEt button on the side of the power head with a pointed object such as a paper clip or a pen tip until the indicator
lights up. (fig.10.2).
9.6.3. Release the RESET button once the red indicator light lights up and immediately press and hold the 'ON' button on the remote
control handle until the vacuum powers on. (fig.10.3).
9.6.4. If the 'ON' button is not pressed and held within a 15 second window, the reset will not be successful. Repeat steps 9.6.2 and 9.6.3
to reset the remote control.
imPortant: When the vacuum is not in use make sure the switch is in the 'O' OFF position and the power cord is disconnected.

10. trouBleShooting

Problem
Vacuum will not operate.
Dust comes from the motor
cover.
Reduced efficiency and motor
speed/vibration.
remote will not operate.
environmental Protection.
recycle unwanted materials instead of disposing of them as
waste. All tools, accessories and packaging should be sorted,
taken to a recycle centre and disposed of in a manner which
is compatible with the environment.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
imPortant: no liability is accepted for incorrect use of this product.
WarrantY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack sealey Limited
Possible causes
no power supply
faulty power cord
container full
Switch in wrong position.
The reuseable cloth filter is
missing or damaged.
Blockage in the nozzle, hose,
or the vacuum inlets. or the dust
filter is blocked by fine dust.
Battery is dead.
Sole uK Distributor, Sealey group,
Kempson Way, suffolk Business Park,
Bury st. Edmunds, suffolk,
iP32 7Ar
Original Language Version
corrective action
check power supply: cord, breakers, fuses
unplug and check the power cord.
if damaged, have it repaired by a professional.
Empty container.
Press the ON 'I' button on the power head.
Attach or replace cartridge filter.
Check nozzle, hose and container inlets for
blockage. Take off the filter and clean it, or install a
new cartridge filter.
replace the battery.
Weee regulations.
Dispose of this product at the end of its working life in compliance
with the Eu Directive on Waste Electrical and Electronic Equipment.
When the product is no longer required, it must be disposed of in an
environmentally protective way. contact your local solid waste
authority for recycling information.
01284 757500