IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT
These instructions apply to LMF-Series valve kits: These Natural gas safety pilot kits are designed to be used with 18 to
30-inch gas logs sets purchased separately as a complete valve kit. These control systems were developed to provide
safe, reliable, user-friendly remote control system for gas heating appliances. Optional LP conversion kits LPK-18, LPK-
24 with pilot orifices are available.
Warning: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual for
assistance or for additional information consult a
qualified installer, service agency or gas supplier.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
- Do not try to light the appliance.
- Do not touch any electrical switch.
- Do not use any phone in your building.
- Immediately call you gas supplier from a
neighbor's phone. Follow the gas suppliers
instructions.
- If you cannot reach your gas supplier call the fire
department.
Young children should be carefully supervised
when they are in same room as the appliance.
Be sure Flue Damper and Glass Doors are fully
open when operating any vented gas log set.
Notice:
Please leave these instructions for the consumer. Retain for future reference
A F
A M E R I C A N
Safety Pilot System for Vented Gas Logs
AF-LMR-R, AF-LMR-RD,
AF-LMF-RV, AF-LMF-RVS
ATTEMPT TO INSTALL OR OPERATE
INSTALLATION AND OPERATING INSTRUCTION
F L A M E
Models:
AF-LMF,
Important: Read these instructions carefully
before starting installation of your log set.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
CALIFORNIA PROPOSITION 65
This product is designed to operate with one of the
following fuel sources: Liquid Propane or Natural Gas.
The fuel used to operate this product, and the products
of combustion of such fuel, can expose you to chemicals
including Benzene which is known to the State of
California to cause cancer, birth defects and other
reproductive harm and Carbon Monoxide which is known
to the State of California to cause birth defects or other
reproductive harm.
(For more information go to: www.p65Warnings.ca.gov.)
WARNING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AF-LMR-R and is the answer not in the manual?

Questions and answers

Summary of Contents for american flame AF-LMR-R

  • Page 1 A M E R I C A N F L A M E Safety Pilot System for Vented Gas Logs Models: AF-LMF, AF-LMR-R, AF-LMR-RD,   AF-LMF-RV, AF-LMF-RVS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE...
  • Page 2 Fig. 2 Carton contents: 1thru 5 Valve Kit 6-Flex Connector 7-Damper Clamp 8-Pilot Assembly 9- Flared Fitting 10- Battery Pack Heat Shield 11 thru 12- Battery Packs 13- CON-1001 14- 5001 15- RCAF-1035 16-RCAF-1020-1 17 thur 19-Batteries 20- Adapter fitting American Flame: AF-LMF Series Valve Kits REV. 11-30-18 Page 2...
  • Page 3 Thermocouple & Pilot Assembly 5001 Transmitter (Touch Screen) LEARN Receiver Shield Damper Clamp REMOTE Receiver Fig. 5 AF-LMF-RD: Manual ON/OFF Gas Valve with solenoid and touch screen ON/OFF remote control American Flame: AF-LMF Series Valve Kits REV. 11-30-18 Page 3...
  • Page 4 11. Install Damper stop (supplied with this valve kit) on edge of damper to prevent it from fully closing. This allows damper to remain slightly open to allow the pilot exhaust to vent outdoors. CAUTION: On all PROPANE installations it is recommended that an inlet pressure regulator be used. American Flame: AF-LMF Series Valve Kits REV. 11-30-18 Page 4...
  • Page 5: Pilot Assembly

    4.0” 2.0” Min. 2.0” Min. 2.0” Min. 2.0” Min. Basket Grate Burner Pan Optional Valve Valve Box Kit Mounting Location Fig. 10 Shows clearances to be maintained inside fire box. American Flame: AF-LMF Series Valve Kits REV. 11-30-18 Page 5...
  • Page 6 REMOTE position. The remote receiver Receiver Slide Button LEARN houses the microprocessor that responds to commands from the transmitter to control system operation. REMOTE Fig. 14 Remove receiver. American Flame: AF-LMF Series Valve Kits REV. 11-30-18 Page 6...
  • Page 7: Lighting Procedure

    - Your system should be checked once a year (at the start of the heating season) for proper operation by a qualified serviceman. - Items to check: Valve operation, pilot operation, switch operation, damper operation, visual check of the burner and gas connections for leaks. American Flame: AF-LMF Series Valve Kits REV. 11-30-18 Page 7...
  • Page 8: Parts List

    18. AA Battery (4 Required for AF-LMF-R & AF-LMF-RD receivers) BATTAA 19. AAA Battery (4 Required for AF-LMF-RD Transmitter) BATTAAA 20. 3/8” to 1/2” adapter (increases 3/8” flare fitting to 1/2” flared fitting) UR3-68 American Flame: AF-LMF Series Valve Kits REV. 11-30-18 Page 8...
  • Page 9: Troubleshooting

    LIMITED WARRANTY American Flame warrants the AF-LMF Valve Kit for 12 months from the date of purchase or installation to the original purchaser to be free from defects in materials and workmanship. Damage to the AF-LMF Valve Kit models caused by accident, misuse, abuse, or installation error, whether preformed by a contractor, Service Company, or owner, is not covered by this warranty.

This manual is also suitable for:

Af-lmr-rdAf-lmf-rvAf-lmf-rvs

Table of Contents