Link MX44-4KUHDE Manual

Link MX44-4KUHDE Manual

Hdmi 2.0 4:4 matrix

Advertisement

MX44-4KUHDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MX44-4KUHDE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Link MX44-4KUHDE

  • Page 1 MX44-4KUHDE...
  • Page 2 HDMI 2.0 4:4 Matrix User Manual Version: V1.0.0...
  • Page 3 Important Safety Instructions...
  • Page 4: Table Of Contents

    Warnings of FCC This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 5 EDID Management ..................13 API Command Control ................... 15 Telnet Control .................. 15 RS232 Serial Control ............... 17 Web UI Control ....................18 Access the Web Interface ............... 18 Matrix Control ..................19 General Setting ..................20 Advanced Setting ................... 26 Warranty Terms and Conditions ..............
  • Page 6: Introduction

    Introduction MX44-4KUHDE is a 4x4 HDMI Matrix with resolutions supported up to 4K@60Hz 4:4:4 8bit and HDCP 2.2 compatibility. It allows four sources to be distributed or switched to four HDMI displays simultaneously. MX44-4KUHDE also provides de-embedded analog audio output from each HDMI output.
  • Page 7: Features

     Supports API command control through RS232 and Telnet connection  Independent DIP switches for manual EDID management Package Contents  MX44-4KUHDE Matrix x 1  IR Remote Handset x 1  USB to UART Cable x 1 ...
  • Page 8 4 x HDMI IN 4 x HDMI OUT 4 4 x AUDIO OUT 1 x IR EXT. Input/Output Connections 1 x LAN 1 x RS232 DB9 port 1 x AC IN Input/Output Video Type HDMI with HDR, HDCP 2.2 800x600 , 848x480 , 1024x768 , 1280x768...
  • Page 9 General Operating 32°F ~ 113°F (0°C ~ 45°C) Temperature/RH 10% ~ 90%, non-condensing -4°F ~ 158°F (-20°C ~ 70°C) Storage Temperature/RH 10% ~ 90%, non-condensing Human-body model: ±8kV (air-gap discharge)/ ESD Protection ±4kV (contact discharge) Power Supply AC 100~240V 50/60Hz Power Consumption (Max) 1018P: 22W;...
  • Page 10: Panel Description

    Panel Description Front Panel Name Description Output Channel Indicates input for output port 1-4. Indicator IR Window Receives signals from IR Remote. Selection Buttons Selects input and output channels.  Left/Right: press to select output channels.  UP/Down: press to select input channels. Enter Button Press to implement the input and output selection.
  • Page 11 AUDIO OUT 1-4 For de-embedding L/R analog audio output. Connect to audio devices via RCA stereo audio cables. IR EXT. IR extension port. Connect an IR receiver cable if required. EDID DIP Switch For EDID Management. RJ45 port; connect to a control system for Web UI and Telnet Control.
  • Page 12: Installation And Wiring

    Note: Before installation, please ensure the device is disconnected from the power source. MX44-4KUHDE occupies 1U space and can be placed on a solid and stable surface or installed on a standard rack mount. Steps for installing the matrix on a rack mount: Position and install the mounting brackets with the mounting screws provided.
  • Page 13 Connect HDMI source devices to HDMI IN 1-4 of the matrix with high- quality HDMI cables (e.g. Blu-ray player, PC, game console, Apple TV, etc.) Connect HDMI OUT Connect HDMI display devices to HDMI OUT 1-4 of the matrix (e.g. TV, projector, LED/LCD display, etc.) Connect AUDIO OUT Connect audio devices to AUDIO OUT 1-4 of the matrix (e.g.
  • Page 16: Front Panel Control

    Front Panel Control The front panel of the MX44-4KUHDE matrix features a LED screen to display the mapping status from each input to each output channel. Power on the matrix and wait until the front panel LED screen shows "1234"...
  • Page 17: Edid Management

    Steps for IR Remote operation: Operate as shown in the diagrams below, using the IR remote. Locate the target output you want to switch inputs for on the remote, numbered 1-4 vertically along the right side. Press the desired input number to select the corresponding input source for your target output.
  • Page 18 MX44-4KUHDE Matrix provides EDID management to output different video resolutions and audio channels for the displays based on the switch settings. By default, the EDID DIP switch is set in Smart EDID position, i.e. all three switches are set to 1 or down position.
  • Page 19: Api Command Control

    Smart EDID ON (Default) For DIP setting "000", EDID can be set via front panel buttons, WEB UI and API commands. Using front panel control, you are able to copy EDID from an HDMI Output to the desired HDMI Input. For instance, to copy EDID of HDMI Output 1 to HDMI Input 2, you should follow steps below: Set the switch to position "000", then press the selection button on the front panel to select Input 2 for Output 1;...
  • Page 20 Connect between the control PC and matrix through telnet. Launch the Run window on your computer, enter "CMD" in the textbox, and then click "OK". The following DOS window will pop up. Input "telnet 192.168.10.254" and press Enter. A new window will display and show "Welcome to use matrix telnet", indicating telnet connection between the matrix and computer is...
  • Page 21: Rs232 Serial Control

    established successfully. Now you could send API command to control matrix through telnet. e.g. bc ↵ Input: It will response: s13 s22 s33 s44 " " means to enter a space "↵ " means to enter a carriage return or a line feed. This command is used to get the matrix mapping status from each input to each output, and the result is that Output 1 corresponds to Input 3, Output 2 corresponds to Input 2, Output 3 corresponds to...
  • Page 22: Web Ui Control

    The Web UI is accessible through a browser, e.g. Chrome, Firefox, Safari, Opera, IE10+, etc. By default, the IP address for MX44-4KUHDE is 192.168.10.254, subnet mask is 255.255.0.0. Default login password for Web UI is "admin".
  • Page 23: Matrix Control

    The Matrix Control allows for input/output switching and Presets configuration. The General Setting allows for setting login, EDID setting, factory default setting and port naming. The Advanced Setting allows for network and password setting, Web UI update, logo customization. Matrix Control The Matrix Control page is used to perform the following functions: ...
  • Page 24: General Setting

    (3) Presets The Presets section saves or loads the input/output switch settings to or from the matrix.  Save: To save input/output settings in the Switch/Switch All section.  Load: To load input/output settings in the Switch/Switch All section. To save an input/output setting to Preset 1: Complete the input and output settings in the Switch section.
  • Page 25  EDID Setting  Port Naming (1) Matrix Setting Login Enter the default password "123456" for Matrix Setting Login in the password box below and Click "Login". The Setting window will display as follows, including EDID Copy, Smart EDID Section and Factory Default button. EDID Copy: Click the drop-down menu to copy EDID from the Output (1-4) to Input(s) chosen.
  • Page 26 Smart EDID: Click ON or OFF to enable or disable the Smart EDID setting. Factory Default: Click to restore the matrix to default settings, and then click "OK". The Notice window will pop up, please reboot the matrix and wait for at least 2 minutes to re-login Web UI.
  • Page 27 Select Port: Click the drop-down menu to choose an Output port (1-4) for EDID setting. Read: Click to read the EDID of the Output port you choose. The following EDID table will appear.
  • Page 28 Write: Click to write the EDID of the Output port you choose to corresponding Input.
  • Page 29 Save as: Click to save the EDID of the Output as bin file to a desired location. Open: Click to open an EDID file. Then you can click "Write" to write the EDID information instead of Output port's EDID to corresponding Input. (3) Port Naming Port Naming allows you to set easy to remember names for inputs and outputs.
  • Page 30: Advanced Setting

     Reset: click to reset changes.  Save All: click to save and apply all changes.  Reset All: click to reset all changes. Advanced Setting Advanced Setting is available to perform the following functions:  Network  Change Password ...
  • Page 31 When "Static" is selected, ensure your PC is in the same network segment as the matrix, i.e. the IP address of your PC should be set as 192.168.x.x. (x is suggested to between 2 to 253) Please wait for 2 to 3 minutes for the matrix LAN module to reboot and reconnect after the network settings are changed.
  • Page 32 Note: DO NOT disconnect the matrix during update process. (4) Log Show: Click to show the Log window at the bottom of the Matrix Control and General Setting Pages. Hide: Click to hide the Log window at the bottom of the Matrix Control and General Setting Pages.
  • Page 33 Click "Upload", the following window will appear. Click "here" to reconnect the system. The new logo will appear on the upper left corner of the screen.
  • Page 34: Warranty Terms And Conditions

    Warranty Terms and Conditions For the following cases LINK Brand shall charge for the service(s) claimed for the products if the product is still remediable and the warranty card becomes unenforceable or inapplicable. The original serial number (specified by LINK Brand) labeled on the product has been removed, erased, replaced, defaced or is illegible.
  • Page 35 WWW.MSTRBRAND.COM...

Table of Contents