REMEHA iBase RF-Base station User Manual page 31

Table of Contents

Advertisement

Available languages

Available languages

Fault indication
Problem
Solution
Fault indication
Problem
Solution
Fault indication
Problem
Solution
tabel 02
Fault indications green status LED
= ½ sec. on.
= ½ sec. off.
T001500-B
Green status LED flashes as follows:
No connection with iSense RF.
-
Check whether the iSense RF indicates a fault or is on.
-
Try to re-establish the connection between the iSense RF and
the Base station; see Chapter 5.
-
If this does not solve the problem, relocate the iSense RF or the
Base station or remove obstacles that can interfere with the RF
signal; see paragraph 3.1.
Green LED flashes as follows:
Power problem
Check whether the boiler is on and whether the Base station is
correctly connected. If the boiler does not support OpenTherm Smart
Power, then connect an external (5 V DC 300mA) adapter.
Green LED flashes as follows:
There is no OpenTherm communication for 60 seconds.
-
Check whether the boiler is on and whether the Base station is
correctly connected.
T001500-B
T001500-B
T001501-B
EN
T001502-B
T001503-B
31