3. Test & debug flow
TEST
Check the AC Voltage
Power PCBA(110V or 220V)
YES
Switch on the Power PCBA
YES
Are the DC Voltage outputs OK?
(5V, 3.3V, 12V, 5.6V MOTOR)
YES
Make sure the main PCBA don't short on
VCCs and switch it on.
YES
Are 3.3V and 1.8V DC outputs normal on
main PCBA?
YES
Connect to PC RS232 Cable and update
the FLASH memory code.
YES
Update FLASH successfully?
YES
A
All manuals and user guides at all-guides.com
NO
Replace power PCBA or AC transformer.
NO
NO
NO
3-4
Repair or Replace Power PCBA
Check the regulators or related diodes.
1. Check 27MHz system clock.
2. Check system reset circuit.
3. Check FLASH R/W enable signal
PRD,RWR.
4. Check RS232 SIGNALS.
5. Check FLASH Memory related circuit.