IMPORTANT
THE HEATER OUTLET GRILLE BECOMES VERY HOT WHILST IN OPERATION.
DO NOT COVER THE OUTLET GRILLE OR ANY PART OF THE APPLIANCE.
FOR USE WITH 230V - 240V 50HZ ELECTRICITY SUPPLY ONLY.
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
KEEP THE INSTRUCTIONS IN A SAFE PLACE.
THEY WILL BE NEEDED WHEN MAINTENANCE OR SERVICING IS REQUIRED.
THIS APPLIANCE MUST BE EARTHED

Advertisement

Table of Contents
loading

Summary of Contents for Living Fire Ilektro Series

  • Page 1 U S E R I N S T R U C T I O N S A N D I N S T A L L A T I O N IMPORTANT THE HEATER OUTLET GRILLE BECOMES VERY HOT WHILST IN OPERATION. DO NOT COVER THE OUTLET GRILLE OR ANY PART OF THE APPLIANCE.
  • Page 2: Table Of Contents

    1250 L,1250S, 1650 L, 2000 L A - ASPECT L - LANDSCAPE S - SUITE HOW TO USE YOUR APPLIANCE Living Fire - 361 Swan Street Rich- 1. IMPORTANT SAFETY INFORMATION mond VIC 3121 - Australia 2. OPERATING INSTRUCTIONS Copyright © 2019 Living Fire 3.
  • Page 3: How To Use Your Appliance

    • WHERE THE ELECTRICITY SUPPLY CABLE HOW TO USE YOUR APPLIANCE HAS TO PASS THROUGH A MASONRY WALL, 1. IMPORTANT SAFETY STONE SURROUND ETC. ENSURE SUITABLE INFORMATION RUBBER BUSHES ARE FITTED AT POSSIBLE WEAR POINTS. • READ ALL OF THE INSTRUCTIONS CAREFULLY BEFORE USING THE APPLIANCE.
  • Page 4 IF YOU ARE INSTALLING YOUR HOW TO USE YOUR APPLIANCE APPLIANCE IN TO AN EXISTING 1. IMPORTANT SAFETY CHIMNEY CAVITY INFORMATION • ENSURE THE FLOOR AREA THE APPLIANCE WILL SIT ON IS FLAT AND FREE FROM • IF THE ELECTRICITY SUPPLY CABLE IS LOOSE MATERIAL DAMAGED DO NOT USE THE APPLIANCE UNTIL IT HAS BEEN REPLACED.
  • Page 5: Operating Instructions

    HOW TO USE YOUR APPLIANCE 2. OPERATING INSTRUCTIONS LED DISPLAY CURRENT SETT FLAME/HEAT/LIGHT WARNING LEVEL DISPLAY PARTS OF THE PRODUCT LH MENU BUTTON RH MENU BUTT MAY GET HOT DURING OPERATION MENU TO TURN THE APPLIANCE ON I/O OPERATE THE STANDBY SWITCH TOUCH DIAL LOCATED ON THE RIGHT HAND SIDE UNDER THE FRONT TRIM,...
  • Page 6 HEAT SETTINGS HOW TO USE YOUR APPLIANCE PRESS THE RH MENU BUTTON TO SELECT THE 2. OPERATING INSTRUCTIONS HEAT CONTROL TO ADJUST THE LIGHT EFFECT CURRENT SETTING SELECT ‘EFFECT’ SETTING WHILE IN LIGHT MODE. THE LH MENU BUTTON WILL SWITCH THE EFFECT ON.
  • Page 7 ADVANCED HOW TO USE YOUR APPLIANCE USED TO TURN ON OR OFF THE DIMMER, 7 DAY 2. OPERATING INSTRUCTIONS TIMER, AND ADAPTIVE HEAT FUNCTIONS. MENU SETTINGS PRESS BOTH MENU BUTTONS UNTIL A MENU APPEARS AT TOP OF SCREEN. 4 SCREEN OPTIONS WILL APPEAR.
  • Page 8 HOW TO USE YOUR APPLIANCE 2. OPERATING INSTRUCTIONS OTHER ADVANCED FUNCTIONS DIMMER THIS FUNCTION DIMS THE SCREEN OF THE HANDSET. TO DIM OR LIGHTEN THE SCREEN PRESS BOTH MENU BUTTONS UNTIL THE MENU OPTION APPEARS. PRESS HOLD THE POWER BUTTON AT ANY TIME WHILST IN THE MENU.
  • Page 9: Maintenance And Care

    HOW TO USE YOUR APPLIANCE HOW TO USE YOUR APPLIANCE 2. OPERATING INSTRUCTIONS 3. MAINTENANCE AND CARE THERMAL SAFETY CUT OUT THE AIR INLET GRILLES ON THE UNDERSIDE AND BACK OF THE APPLIANCE SHOULD IF THE SAFETY CUT OUT FOR THE HEATER BE UNOBSTRUCTED.
  • Page 10 HOW TO USE YOUR APPLIANCE 3. MAINTENANCE AND CARE CLEANING THE OUTLETS • ENSURE THE APPLIANCE IS UNPLUGGED • CLEAN THE AIR OUTLET GRILLES REGULARLY WITH A SOFT CLOTH OR THE NOZZLE OF A VACUUM CLEANER • DUST BUILD-UP CAN INHIBIT EFFICIENT PERFORMANCE OF THE FAN AND LEAD TO THE SAFETY CUT-OUT OPERATING.
  • Page 11: How To Install Your Appliance

    HOW TO INSTALL YOUR APPLIANCE 4. TECHNICAL SPECIFICATION MODEL 750 L 750 A 750 S 900 L 900 A WEIGHT VOLTAGE 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz BATTERY HANDSET TRANSMITTER 12 V MN 21/23 12 V MN 21/23 12 V MN 21/23 12 V MN 21/23 12 V MN 21/23 FLAME PICTURE ELECTRICAL...
  • Page 12: General Installation

    FITTING THE APPLIANCE HOW TO INSTALL YOUR APPLIANCE TAKE CARE WHEN LIFTING THE APPLIANCE, 5. GENERAL INSTALLATION OBTAIN ASSISTANCE IF REQUIRED AND ALWAYS FOLLOW SAFE MANUAL HANDLING TECHNIQUES. NOTE: INSTALLATION SHOULD BE CARRIED OUT BY A TRAINED INSTALLATION WHEN IN DOUBT CONSULT YOUR RETAILER OR TECHNICIAN.
  • Page 13: Configuring Your Window

    • LOCATE THE BLANKING PLATE MOUNTING HOW TO INSTALL YOUR SCREWS ON EITHER SIDE OF THE APPLIANCE APPLIANCE. AS SHOW ON THE IMAGE 6. CONFIGURING YOUR WINDOW BELOW. • REMOVE THE 6 SCREWS USING THE THE CONFIGURATION OF CORRECT SCREWDRIVER. •...
  • Page 14: Installation

    • THE APPLIANCE SHOULD IDEALLY BE HOW TO INSTALL YOUR LOCATED CLOSE TO A SUITABLE MAINS APPLIANCE SOCKET TO ENABLE CONNECTION. THE 7. INSTALLATION ELECTRICAL SOCKET MUST BE EASILY ACCESSIBLE TO ALLOW DISCONNECTION WHEN THE APPLIANCE IS FITTED. POSITIONING YOUR APPLIANCE •...
  • Page 15 • REMOVE THE WALL BRACKET SCREWS AND HOW TO INSTALL YOUR ROTATE THE BRACKET AND ROTATE AS APPLIANCE SHOWN IN THE IMAGE BELOW 7. INSTALLATION • REATTACH THE BRACKETS AS SHOWN SO THEY ARE FLAT AGAINST THE FIXING WALL POSITIONING YOUR APPLIANCE AND ALIGN WITH THE MOUNT HOLES ON YOUR APPLIANCE.
  • Page 16: Setting The Fuel Bed

    • TO ACCESS THE LOG FUEL BED THE FRONT HOW TO INSTALL YOUR GLASS WILL NEED TO BE REMOVED. SEE APPLIANCE REMOVING GLASS INSTRUCTIONS ON PAGE 8. SETTING THE FUEL BED • LOG INSTALLATION IS TO BE CARRIED OUT • UNPACK THE BOX OF LOGS PROVIDED. THE BY A QUALIFIED INSTALLATION TECHNICIAN LOGS ARE MADE FROM CERAMIC AND ARE FRAGILE.
  • Page 17 750 LANDSCAPE & HOW TO INSTALL YOUR APPLIANCE 6. SETTING THE FUEL BED LOG POSITIONS FRONT 950 ASPECT 950 LANDSCAPE FRONT FRONT 1250 FRONT 1650 FRONT 2000 FRONT...
  • Page 18: Electrical Connection

    HOW TO INSTALL YOUR • CONNECT THE PROVIDED IEC POWER CORD TO THE APPLIANCE AND FASTEN THE APPLIANCE POWER SOCKET CLAMP INTO PLACE 10. ELECTRICAL CONNECTION • NOTE: DO NOT OVER TIGHTEN THE WARNING POWER CABLE CLAMP. TIGHTEN THE NUT PROVIDED TO ENSURE THE POWER ENSURE THE APPLIANCE IS FULLY SOCKET CANT BECOME LOOSE.
  • Page 19: Servicing Instructions

    IF THE HEATER STOPS OPERATING WHILST SERVICING INSTRUCTIONS THE FLAME EFFECT CONTINUES NORMALLY, 11. GENERAL INFORMATION THIS INDICATES THAT THE E.S. CONTROL IS IN OPERATION. THE E.S. CONTROL CAN ONLY BE RE-SET AFTER THIS APPLIANCE MUST ONLY BE SERVICED THE APPLIANCE HAS COOLED DOWN. BY A SUITABLY QUALIFIED PERSON.
  • Page 20: Fault Finding

    FAULT: THE HEATING DOES NOT TURN-ON SERVICING INSTRUCTIONS WHEN YOU SELECT HEATING MODE BUT THE 12. FAULT FINDING FLAME EFFECT IS RUNNING. A)CHECK THE BATTERIES IN YOUR HAND SET. THE RED LED MUST BE SHOWING BRIGHTLY. OPERATE APPLIANCE BEFORE COMMISSIONING B)TRY SELECTING HEATING MODE AGAIN, BUT 1.
  • Page 21: Servicing Requirements

    1. SPRAY ANTI STATIC ON THE BACK OF SERVICING INSTRUCTIONS THE FIRE BEHIND THE SCREEN AND ON 13. SERVICING REQUIREMENTS THE SILK. 2. ATTACH THE SILK AND CLIP BACK INTO ITS ORIGINAL POSITION. 3. CLEAN THE EFFECTS SCREEN AND TO SERVICE THE APPLIANCE PLEASE OUTER SCREEN WITH SCREEN CLEANER FOLLOW THE STEPS AS DETAILED: AND CLOTH.
  • Page 22: Removing The Glass

    REMOVING THE TRIM BRACKETS SERVICING INSTRUCTIONS 14. REMOVING THE GLASS REMOVING THE FRONT TRIM USING A SMALL METAL PIN OR SCREWDRIVER, CAREFULLY LIFT THE FRONT TRIM IN THE WARNING CORNERS TO GET UNDER THE TRIM BEFORE UNDERTAKING ANY WORK ON THE APPLIANCE: SWITCH OFF THE APPLIANCE AND ISOLATE IT FROM THE MAINS BY UNPLUGGING THE UNIT.
  • Page 23: Removing The Glass

    REMOVING THE GLASS SERVICING INSTRUCTIONS USING TWO GLASS LIFTING SUCTION PADS 14. REMOVING THE GLASS GRIP THE FRONT GLASS IN THESE LOCATIONS RELEASING THE GLASS WARNING: ALTHOUGH THE GLASS PANEL HAS BEEN TREATED WITH SAFETY EDGES PLEASE TAKE CARE WHEN HANDLING THE GLASS. AVOID CONTACT WITH CORNERS AND IF NECESSARY WEAR PROTECTIVE GLOVES.
  • Page 24: Replacing Fuel Bed Leds

    SERVICING INSTRUCTIONS SERVICING INSTRUCTIONS 15. REPLACING FUEL BED LEDS 14. REMOVING THE GLASS • TO ACCESS THE FUEL BED LEDS, REMOVE WARNING THE FRONT GLASS AS DETAILED ON PAGE BEFORE UNDERTAKING ANY WORK ON THE • REMOVE ANY FUEL EFFECT MATERIAL APPLIANCE: SWITCH OFF THE APPLIANCE CAREFULLY, AT SET ASIDE.
  • Page 25: Replacing The Power Plate

    • THE LED CABLE LINKING THE FUEL BED SERVICING INSTRUCTIONS PLATE CAN REMAIN ATTACHED. ENSURE 15. REPLACING FUEL BED LEDS YOU ROTATE THE FUEL BED PLATE OUT OF THE APPLIANCE AND SET ASIDE ENSURING NO TENSION IS APPLIED TO THE LED CABLE. FUEL BED LED WIRING BLOCK DIAGRAM •...
  • Page 26: Removing Top Led Bar

    SERVICING INSTRUCTIONS SERVICING INSTRUCTIONS 18. REMOVING THE INNER 17. REMOVING TOP LED BAR SCREEN ASSEMBLY • TO REMOVE THE TOP LED BAR REACH INTO • TO REMOVE THE INNER SCREEN ASSEMBLY THE APPLIANCE AND LOCATE THE LED LOCATE THE 4 FIXING POINTS POWER CABLE ON THE RIGHT HAND END •...
  • Page 27: Removing The Fan Assembly

    SERVICING INSTRUCTIONS 19. REMOVING THE FAN ASSEMBLY • TO REMOVE THE FAN ASSEMBLY FIRST REMOVE THE EFFECT LED BAR AND FLAME MATERIAL FROM THE FAN ASSEMBLY AT THESE POINTS. RETAIN THE SCREWS FOR RE-ASSEMBLY • DO NOT UN CLIP THE FLAME EFFECT MATERIAL FROM THE UPPER HANGING BAR. •...
  • Page 28: Removing The Heater

    SERVICING INSTRUCTIONS 20. REMOVING THE HEATER ASSEMBLY • TO REMOVE THE HEATER ASSEMBLY, LOCATE THE 4 NUTS ON THE INSIDE TOP OF THE APPLIANCE. • THE NUTS AND WASHERS ARE M5 SIZE. USE AN 8mm SOCKET WITH AN EXTENSION TO RELEASE THE NUT.
  • Page 29: Wiring Diagram

    SERVICING INSTRUCTIONS 21. WIRING DIAGRAM LEDS SWITCH DATA JACK...
  • Page 30: Appliance Dimensions

    FRONT ENCLOSURE DIMENSIONS • ALL DIMENSIONS ARE IN MILLIMETRES • APPLIANCES 750 S, 900 S, 1250 S (SUITE) ARE SUPPLIED WITH THEIR OWN ENCLOSURE AND SHOULD NOT BE BUILT IN ANY OTHER ARRANGEMENT • DIMENSIONS SHOWN ARE FOR THE ENCLOSURE ONLY. THESE DIMENSIONS ARE REQUIRED FOR THE APPLIANCE TO OPERATE.
  • Page 31: Enclosure Dimensions

    APPLIANCE DIMENSIONS NOTE: ALL DIMENSIONS ARE IN MILLIMETRES APPLIANCE 750 A 750 L 750 S 900 A 900 L 900 S 1250 L 1230 1262 1250 S 1230 1262 1650 L 1625 1657 2000 L 1975 2007...