aeration openings/ grids to the storage compartment chosen for the
dispenser, in order to clear out the heat produced by cooling system.
The dispenser should not be placed near direct or undirect heat sources.
Warning
the power supply cable and the water supply must
absolutely be kept separated. Be careful while moving the dispenser
before the installation, avoiding shocks, falls or accidental hit that
could damage internal circuits.
The undercounter dispenser WatHome20 is connected to draft
column with 8mm diameter tubing. The maximum distance
suggested to preserve good performances is 2 meters between the
column and the dispenser.
In order to avoid condensation, it is important to insulate outlet
tubing headed for the draft column
12