3. Preset frequencies for various destinations
(random preset memory)
CH
BAND
1
FM 87.5 MHz
2
FM108.0 MHz
3
FM STEREO
FM 98.0 MHz
4
FM 90.0 MHz
5
FM106.0 MHz
CH
BAND
6
AM 530 kHz
7
AM1720 kHz
8
AM
AM 990 kHz
9
AM 600 kHz
10
AM1400 kHz
CH
BAND
16-35
——————
36
FM106.0 MHz
37
FM 90.0 MHz
38
FM MONO
FM 98.0 MHz
39
FM108.0 MHz
40
FM 87.5 MHz
The slant line sections of the table store no memory.
4. Electronic volume Test Mode (TEST 3)
When this test mode is obtained, the following display lights for one
second.
In this mode, volume is Volume -14 dB (STEP 23), FLAT AND X-BASS
ON, and start-up function to CD, respectively. The button operations in
the test mode are the same as those of ordinary operation except vol-
ume UP/DOWN.
1) The display is the same as that of ordinary operation except test
mode setting.
2) Unlike the ordinary state, the volume is controlled with the Volume
UP/DOWN button in accordance with the following three steps.
Volume- ∞ (STEP 0) <-> Volume-14 dB (STEP 23) <-> Volume-0
(STEP 30)
3) X-BASS is switched when button is pressed.
5. Timer test Mode (TEST 4)
When this test mode is obtained, the following display lights for one
second.
Set the current time and timer time according to the following proce-
dure to reproduce the timer.
1. Set the current time to 1:00, the timer to ON time 1:05, the function
to CD, and volume to STEP 12, respectively. One minute is
counted as one second, and the timer is reproduced. The fade-in
(when playback is started) is executed at a rate of one step for 1
sec. After completion of fade-in, the fade-out is executed at a rate
of one step for 1 sec (WAIT 1 sec inserted).
After completion of fade-out, the power is turned off (after WAIT 1
sec), and the mode is shifted to the standby.
The display during operation is the same as that of ordinary timer
operation.
FM
FM
FM
6. FL Test Mode (TEST 5)
When the FL test mode is obtained, all the FL segments are lighted.
Then pressing the "PLAY" button switches display as below.
————–
Lighting of all segments
Lighting of odd segments
Lighting of even segments
__________
7. Button input diagnosis Test Mode (TEST 6)
When the test mode is obtained, the following is displayed.
(STAND-BY AND DEMO OFF STATUS)
This test mode is intended to check whether all the main unit buttons
can be detected. Accordingly, in this test mode, it is checked whether
the "ON/STAND BY" button was pressed after all the buttons shown
below were pressed. If the result is OK, OK is displayed. If any one of
keys was not pressed, an error is displayed. In both cases of OK termi-
nation or error termination, the mode is shifted to the standby mode if
the "ON/STAND BY" button is pressed subsequently.
All models using this type of microcomputer are not always provided
with the same buttons. Since the buttons used are different depending
on models, types of buttons to be used are determined by whether
SURROUND, and an electric lid are available at the initial setting by
MODEL port.
The order of buttons to be pressed is not determined. Accordingly, it is
checked whether all buttons have been pressed.
1. PU-IN buttons: REW/PRESET DOWN + CD STOP
Since this model is provided with SURROUND (HAVE OR NOT),
and electric CD lid, the following 10 buttons are detected as all but-
tons.
PLAY, X-BASS/DEMO, FUNCTION, VOLUME UP/DOWN, MEM-
ORY/SET, REW, FF, STOP, DISK TRAY OPEN/CLOSE
The OK/ERROR display of test result is as follows.
2 – 4
CD-MPS440W