Kohler K-13460 Installation Manual page 6

Electronic lavatory faucet
Hide thumbs Also See for K-13460:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting (cont.)
Symptoms
Probable
Causes
2.
Low flow.
A. Filter is
plugged.
B. Supply
pressure is
low.
C. Aerator is
plugged.
3.
Constant
A. Filter is
water flow.
plugged.
B. Diaphragm
seal is
damaged or
dirty.
C. Solenoid is
not working.
4.
Sporadic
A. The faucet
water flow.
is angled
incorrectly to
deck or
misaligned
with user area.
B. The wires
are pinched or
damaged.
5.
Sensor flashes
A. The battery
once
power is low.
approximately
every 2
seconds. The
product
continues to
operate.
6.
Sensor flashes
A. The battery
once
power is
approximately
insufficient to
every 2
allow the
seconds. The
product to
product does
operate.
not operate.
1102759-2-B
Recommended Action
A. Clean or replace the filter.
B. Check incoming water pressure.
Pressure should be at least 20 psi
(137 kPa).
C. Remove the aerator and clean it.
For calcium/mineral deposits, soak
the aerator plastic insert in a 50:50
mixture of vinegar and water. Soak
only the insert and no other
components.
A. Clean or replace the filter.
B. If the diaphragm is cut or torn,
order a new diaphragm assembly.
Clean or replace the diaphragm.
C. Order and install a new
solenoid assembly.
A. Verify that the faucet is
mounted according to the
installation directions. Ensure that
the faucet is installed in a position
that is above the rim of the
lavatory.
B. Remove the spout and verify
that the wires are tucked inside the
spout before reassembling.
A. Remove faucet from body and
replace batteries. Use two standard
AAA batteries.
A. Remove faucet from body and
replace batteries. Use two standard
AAA batteries.