General Specification
µP based, PID temperature controller with OUT and ALARM outputs
Auto-tuning for PID parameters
Sensor type: T/C (J,K,T,S,R), Pt100, selectable, multi-input
Selectable control type: P, PI, PD, PID or ON-OFF
Automatic "Overshoot" elimination in PID mode "Anti-windup"
" Anti-windup"
Upper and Lower limit for SET and ALARM settings
Selectable relative, absolute or band alarm
ON-delay for OUT in cooling mode
Displays SET and PROCESS values
Cold-junction compensation for T/C
Line compensation for Pt100
Excellent linearity with C/mV and C/W look-up tables
Input "Offset" feature
Password protection
High accuracy
EEPROM memory to store settings
Optional SSR output
Easy connection with plug-in connectors
Connection
Warning: If 2 wire Pt100 is used, connect compansation lead to measuring lead.
!
(DT-96/ DT-Y/DT-D: 17-18, DT-72: 13-14, DT-48: 10-11)
Temperature
Controller
DT-72
Temperature Controller
DT-96
3
100 .. 240 VAC
50/6Hz 6VA
4
no
5
Out
6
7
nc
8
no
9
Alarm
nc
10
o
o
3
100 .. 240 VAC
50/6Hz 6VA
4
13
no
5
+
14
Out
6
15
-
nc
7
T/C
Pt100
no
8
!
Out & Alarm:
Alarm
9
250VAC
max. 2A
nc
10
resistive load
Temperature Controller
DT-48
!
17
no
18
+
Out
19
-
nc
T/C
Pt100
Alarm
Out & Alarm:
250VAC
max. 2A
resistive load
DT-96 / DT-72 / DT-48 / DT-D / DT-Y
AUTO-TUNE PID TEMPERATURE CONTROLLER
no: Normally open
nc: Normalde closed
Temperature
Controller
DT-Y
!
1
100 .. 240 VAC
50/6Hz 6VA
2
10
3
Temperature
11
Controller
+
4
DT-D
12
-
5
T/C
Pt100
6
Out & Alarm:
7
250VAC
max. 2A
resistive load
1
3
100 .. 240 VAC
50/6Hz 6VA
4
17
no
5
+
18
Out
6
19
-
nc
7
T/C
Pt100
no
8
Out & Alarm:
!
Alarm
9
250VAC
max. 2A
nc
10
resistive load
3
100 .. 240 VAC
50/6Hz 6VA
4
17
no
5
+
18
Out
6
19
-
nc
7
T/C
Pt100
no
8
Out & Alarm:
!
Alarm
9
250VAC
max. 2A
nc
10
resistive load
MADE IN TURKEY
ENG

Advertisement

loading
Need help?

Need help?

Do you have a question about the DT-96 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tense DT-96

  • Page 1 DT-96 / DT-72 / DT-48 / DT-D / DT-Y AUTO-TUNE PID TEMPERATURE CONTROLLER General Specification µP based, PID temperature controller with OUT and ALARM outputs Auto-tuning for PID parameters Sensor type: T/C (J,K,T,S,R), Pt100, selectable, multi-input Selectable control type: P, PI, PD, PID or ON-OFF Automatic “Overshoot”...
  • Page 2 Technical Specification DT-96:96x96, DT-72:72x72, DT-48:48x48, DT-D, DT-Y:48x96mm Dimension Display 4 Digits 7 Segment (PV), 4 digits 7 Segment (SV) Sensor Type J,K,T,S,R type T/C, Pt100 selectable -100 .. 600 C, J type T/C, (Inpt=J), -100 .. 1300  C, K type T/C, (Inpt=k) Measuring Scale -100 ..
  • Page 3 Programming Parameter: Press for 2 sec. Upper Display Upper Display Enter 262 to start Enter 162 to pass to CodE CodE Enter 162 “auto-tune” parameters prog. mode. Back J: J Type T\C, K: K Type T\C “tunE” T: T Type T\C, S: S Type T\C Inpt Sensor Type (1) R: R Type T\C, Pt: Pt100...
  • Page 4 Programming Heat SET and Absolute Alarm SET: Press 2 sec. Upper Display Heat SET; H.SEt Lo.L .. UP.L (Process SET) value is set Lo.L .. UP.L AL.tY= Displayed if Ab.AL = Yes; rel, -rel A.SEt Absolute Alarm SET Value Lo.L .. UP.L bnd, -bnd is set Lo.L ..

This manual is also suitable for:

Dt-dDt-yDt-72Dt-48