COMPLIANCE O u r a p p l i a n c e a r e c o m p l i a n c e a t : G a s d i r e c t i v e 9 0 / 3 9 6 / C E E E l e c t r o m a g n e t i c d i r e c t i v e c o m p a t i b l e 8 9 / 3 3 6 / C E E 0694 L o w - t e n s i o n d i r e c t i v e 7 3 / 2 3 / C E E...
Page 3
Kind Technical We thank you for choosing the appliance. We can assure you its performance will be long lasting, reliable when it is installed and used properly (manufacturer’s guidelines are followed). Good work and thanks The Manufacturer. WARRANTY Provided that it is fitted in accordance with the Manufacturer's instructions, this appliance benefits from the statutory warranty.
GENERAL INFORMATIONS After removing the packaging, check the integrity of The appliance should be serviced at least once a the contents. In case of discrepancies, contact the year. Agency that sold the appliance. This booklet is an integral part of the appliance and The appliance must be installed by an authorised must therefore be carefully looked after and company pursuant to Law no.
APPLIANCE DESCRIPTION Note: At request the apparatus can be furnished The appliance is a gas radiator that heat up the already arranged at GPL. atmosphere. It has an intake of air that goes in the combustion It also has an electrical device that allows you to do chamber type C.
STRUCTURE 21 22 Safety thermostat Pressure switch Heat exchanger Battery holder (buffer batteries) Upper cover Control unit Technical data plate Combustion fan Exchanger cover Ignition electrode Glass pipe Detection electrode Gas valve Air extraction pipe Power plug Digital control Gas tap “Split”...
CONTROL PANEL DESCRIPTION OF KEYS a - Switch on the appliance (key 3); b - Press MENU key (key 5); c - Press DOWN key (key 2) to move the cursor onto the required menu line; d - Press SELECT key (key 5); note: keys 1, 2, 4 and 5 acquire different functions in the different menus.
Page 11
RECEIPT OF PRODUCT The appliance is supplied protected by cardboard packaging containing: n. 1 Appliance n. 1 Digital chronothermostat n. 1 STANDARD pipe kit n. 1 Metal template n. 2 Bracket n. 1 Documents envelope: n. 1 User instruction booklet n.
Page 12
Verify Tube kit When the appliance is being installed be sure that all the tubes are adjusted for the installation you want done. The tube kits available are: MODEL description CODE KIT std. EXHAUST & INTAKE Ø 54mm (1 INDIVIDUAL) T P 5 4 0 P 0 0 0 0 0 f i a m m e l l a KIT special EXHAUST &...
WEIGHT & DIMENSION fiammella DESCRIPTION Depth ( A ) Height ( B ) 1070 Width ( C ) Weight INSTALLER...
Page 14
INSTALLATION GENERAL INFORMATIONS This apparatus is tin respect to the environment; the air is intake from the outside. -When the appliance is being installed do not use other pieces that are not give from the manufacturer. -Don’t let the electrical cable touch heated parts, like the grill or the intake &...
Page 15
Max tube length has been respected, even the Max loaded loss provided (See table). 32 mm 1038 (*) - Sum of the pressure leak both Fiammella MODEL air suction and gas exhaust pipes. Single terminal (**) - MAX two dye-cast curve: 1 for intake and 1 for the unloaded.
Page 16
FITTING THE METAL TEMPLATE To establish the position of the metal template of the APPLIANCE, use the same template moving it up against the chosen wall or corner. WALL installation: - move the template (1) up against the wall and level; M i n .
Page 17
Outside grill assemblage (cod 7000000350) To assemble the grill you only need the inserts, and the steeliness steel flange. Ø 54 Assemblage SDP protection (cod 7000000365) The assembling is execute in the following way: -After you have drilled on the outside wall put the protection with mortar -Assemblage the terminal tube with the equipment screws...
Page 18
(see below chart). (*) - Sum of the pressure leak both MODEL Fiammella air suction and gas exhaust pipes. Single terminal (**) - MAX two dye-cast curve: 1 for intake and 1 for the unloaded.
Page 19
Chances A1/A2 tube assemblage in wall. This solution can be adapted when the wall thick- Before you wall up the tubes, provide to ness consent to execute the trace for the connection insulate the exhaust fume tubes, with strong tubes, and can be realize in two ways: materials resistant at a greater temperature of 200 °C (ex.
Page 20
Group adapter connection tube -- With Ø 54 mm tubes - Adapting the length tube; to the wall space so it increases 25 mm, then cut it. - Open the group adepter connections disassemble the two flanges (1) unscrew the screws (2) take off the reductions (3 only for the 0 32mm tubes) then assemble the group.
Page 21
Chance A2 with Ø 54 mm tubes To install the fume exhaust and air extraction pipes: - mark the centre (A) and make the hole B (Ø 65 mm for the pipe Ø 54 mm). - make the recess in the wall to house the curve and remaining pipes.
Page 22
Chance B – outside tube assemblage This solution can be adapted when the exhaust fume tubes and the comburent air intake tubes are to the outside. M I N 2 0 0 Before you wall up the tubes, provide to the insulate the exhaust fume tubes, with strong materials resistant at a 200°C temperature (ex.
APPLIANCE ASSEMBLAGE The proper function of the appliance has to be cou- +25mm ple to the tube Ø 54 mm it foresees the application of the diaphragm (1) supplied with the apparatus equip- ment. The diaphragm has to be inserted inside the air intake Ø...
Page 24
FITTING THE REMOTE DIGITAL CONTROL To ensure correct installation of the remote control in the position desired by the user, follow these instruc- tions: - Select the position of the remote control: - on board the appliance - away from the appliance (max 2.95 m); - Install the remote control - Remote control on-board appliance This solution (standard) has been designed to detect...
Page 25
POWER CONNECTIONS The appliance must be installed by companies approved pursuant to Law no. 46 dated 5 March + 2cm 1990. Upon completing the installation, such compa- nies must issue a declaration of installation confor- mity in accordance with applicable national and local laws (see art.
GAS CONNECTION Check on the technical label for the kind of gas that the appliance uses. Use the proper gas tubes and pipe fitting. The etching under the appliance is a 3/8" M UNI ISO 7/1. When the gas alimentation, is on the right side of the appliance for eventuating any problems use a nipples.
FIRST SERVICE START After performing all the preparation operations for ini- tial start-up, to start the appliance: - make sure the fuel tap is open; - fit the plug in the socket on the appliance; - move the master switch (if fitted) to "on" or fit the power plug in the wall socket;...
- The gas pressure value has to be as in the table. MODEL G 2 0 G 3 0 G 3 1 nom. / red. nom. / red. nom. / red. fiammella 12/7,5 28,8/17 36,7/21 mbar - The apparatus execute a stop, and next restart.
-Verifying that the values on the nozzles ore as in the table below. MODEL METHANE L P G fiammella Ø 1 , 1 0 0 , 6 2 -Reassemble the cap with the burner, in the same way that you dissembled don’t forget the O-ring (7) and disk (8) that goes around the cap.
G 3 1 - Loosen the pressure screw (1) connect the mano- nom. / red. nom. / red. nom. / red. meter and verified the pressure value is included between 17/25mbar (like indicated in the table) then fiammella 12/7,5 28,8/17 36,7/21 mbar close the screw after that the manometer tube is pul- led away.
Regulation min pressure Room Thermostat PROBE offsetting Proceed to the minimum pressure regulation after This function permits offsetting the difference that you regulated the max pressure! between the temperature read at the point where the To make a regulation operate on the screw that is on sensitive element of the room temperature probe is the modulator body (4).
blow next to the injector; it will come out all the resi- dues and the impurity caused from the burner. Check all the injectors if are good. Don’t use metallic utensil. Cleaning Electrode The ignition electrode (1) and revelation (2) have to be cleaned very carefully, after a period of time they get fragile because of the work they have to perform.
Page 33
Fan replacement Follow the indication to replace the fan - Take off the electrical connectors that are on the fan motor (1). - Take off the ground connector that is on the fan motor. - Unscrew the screws (2) that fasten the fan to the supports (3) - Replace the fan then after do the assemblage Replacing a burnt out protection fuse...
Page 34
Replacing the safety thermostat (manual resetting) Follow the instructions below to remove and refit the thermostat: - remove the thermostat retention bracket (1) by loo- sening the screw (2). - disconnect the power connectors from the Safety thermostat (3). - refit the thermostat unit in reverse fitting sequence; The safety thermostat trips if the convection fan is not working properly or anomalous overheating occurs and/or the outflowing air temperature reaches...
Page 35
Replacing the SIT gas valve Follow the instructions below to remove and refit the valve: - remove the power connections. - loosen the retention nut that secures the burner pipe (1) to the valve body (2). - loosen the retention nut that secures the mains gas pipe to the valve body.
Page 36
DISASSEMBLY & RIASSEMBLY OF THE SKIRT Removing the casing Remove the fastening screws (1) of the cover (2). Carefully raise and remove the flame cover glass (3) with rear support fastenings. Raise and remove the two side panels (4), freeing these of the fastening tangs (5).
Page 37
FAULT CAUSE REMEDY The thermostat does not engage. Thermostat programming wrong Adjust thermostat: - increase - decrease. Unfavourable appliance position. Change appliance position PROBE offset faulty. Offset correctly Upper or lower grille blocked Clean / Free SPLIT probe has come out of seat. Position correctly INTEGRATED room probe faulty Replace Probe or Digital Chrono...
USEFUL INFORMATION Venditore Sig. Via. tel. Installatore Sig. Via. tel. Servizio Tecnico di Assistenza Sig. Via. tel. Data Intervento CUSTOMER SERVICE...
Page 39
Lei potrà, in qualsiasi momento, richiederci l’aggiornamento o la cancellazione Programmed maintenance contract scrivendo a Italkero Srl, via Lumumba 2 - 41100 Modena. L'Utente dichiara di accettare tutte le condizioni di garanzia, di aver constatato il L'Utilisateur déclare d'accepter toutes les conditions de garantie, d'avoir constaté...