Table 2: Art Cool Gallery (SF Frames) Indoor Unit General Data
Model No.
Cooling Mode Performance
Capacity (Btu/h)
Max. Power Input
(W)
1
H/M/L Power Input at Factory Default (W)
Heating Mode Performance
Capacity (Btu/h)
Max. Power Input
(W)
1
H/M/L Power Input at Factory Default (W)
Entering Mixed Air
Cooling Max (°F WB)
2
Heating Min (°F DB)
2
Unit Data
Refrigerant Type
3
Refrigerant Control
Sound Pressure
dB(A) (H/M/L)
4
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Communication Cable
(No. x AWG)
5
Fan
Type
Quantity
Motor/Drive
Airflow Rate H/M/L (CFM)
Piping
Liquid Line (in., O.D.)
Vapor Line (in., O.D.)
Condensate Line (in., I.D.)
EEV: Electronic Expansion Valve
Power wiring is field supplied and must comply with the applicable local and national
codes.
This unit comes with a dry nitrogen charge.
All capacities are net with a combination ratio between 95-105%.
Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change
without notice. Current certified ratings are available at www.ahridirectory.org.
Max. power input is rated at maximum setting value.
1
Low ambient performance with LGRED° heat technology is included in Multi V 5 Air
2
Source Units produced after February 2019.
ARNU093SFA4
9,600
35
28 /16 / 10
10,900
35
28 /16 / 10
76
59
R410A
EEV
38 / 32 / 27
33.1
38.1
2 x 18
Turbo Fan
1
Brushless Digitally Controlled / Direct
286 / 222 / 148
1/4 Flare
1/2 Flare
5/8
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
ART COOL
ARNU123SFA4
12,300
35
32 / 20 /12
13,600
35
32 / 20 /12
76
59
R410A
EEV
44 / 38 / 32
33.1
38.1
2 x 18
Turbo Fan
1
328 / 272 / 212
1/4 Flare
1/2 Flare
5/8
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
3
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F)
under section 608 of CAA.
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4
All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded
5
and must comply with applicable local and national codes. Ensure the communication
cable is properly grounded at the master outdoor unit only.
communication cable at any other point.
GALLERY
TM

General Data

Do not ground the ODU-IDU
13