5.0 RF Connector Installation:

1. All RF connectors including the power port connector are standard KS-type connectors.
Refer to Figure 2.
2. Using a ½ inch (12mm ) wrench, remove port covers from RF ports and power port on the
housing base.
3. The center conductor seizure screws (Phillips screw) are located through the module.
Loosen, but do not remove the seizure screw.
4. Measure the stinger to verify that it is 1.0 inches (25mm). Refer to Figure 3.
5. If you are going to apply shrink tubing to weatherproof the finished connection, slip a section
of shrink tube over the end of the cable now.
6. Insert the KS connector and cable to the Housing base and tighten connector. KS connectors
should be tightened per manufacturer's specifications.
7. Using a Philips screw driver tighten the seizure screw.
8. Position the shrink tubing over the connector and apply heat to shrink it in place.
6.0 Power Cable Installation:
1. The LBN200 can be powered either with 120VAC mains or HFC power supply with AC input
between 40 and 90 VAC. AC power is brought into the Node through the dedicated power port.
2. Follow "RF Connection Installation" section to install Power cable.
CAUTION! AC voltages in the range of 40 to 90 V AC. Shut down external AC power before
connecting or disconnecting power cables to the node.
Figure 2
1.0 in
(25mm)
Figure 3
5
LBN200 RFoG ONU
User Manual
LBN200 April 2013_rev1