Labkotec OilSET-1000 Installation And Operating Instructions Manual

Oil separator alarm device with set/dm3al sensor

Advertisement

Labkotec Oy
Myllyhaantie 6
FI-33960 PIRKKALA
FINLAND
Tel:
+358 29 006 260
Fax: +358 29 006 1260
23.9.2019
Internet:
www.labkotec.fi
D15492AE-2
1/13
OilSET-1000
Oil Separator Alarm Device with SET/DM3AL sensor
Installation and Operating Instructions
Copyright © 2019 Labkotec Oy
We reserve the right for changes without notice

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OilSET-1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Labkotec OilSET-1000

  • Page 1 Tel: +358 29 006 260 Fax: +358 29 006 1260 23.9.2019 Internet: www.labkotec.fi D15492AE-2 1/13 OilSET-1000 Oil Separator Alarm Device with SET/DM3AL sensor Installation and Operating Instructions Copyright © 2019 Labkotec Oy We reserve the right for changes without notice...
  • Page 2: Table Of Contents

    Installation and Operating Instructions TABLE OF CONTENTS 1 GENERAL ......................3 2 INSTALLATION ....................4 2.1 OilSET-1000 control unit ................4 2.2 SET/DM3AL sensor ..................5 2.3 Cable joint ....................5 3 OPERATION AND SETTINGS ................6 3.1 Operation ..................... 6 3.2 Factory settings ....................
  • Page 3: General

    D15492AE-2 Installation and Operating Instructions GENERAL OilSET-1000 is an alarm device for monitoring the thickness of the oil layer accumulating in an oil separator. Depending on the order, the delivery consists of OilSET-1000 control unit, SET/DM3AL sensor and a cable joint.
  • Page 4: Installation

    Installation and Operating Instructions INSTALLATION OilSET-1000 control unit OilSET-1000 control unit can be wall-mounted. The mounting holes are located in the base plate of the enclosure, beneath the mounting holes of the front cover. The connectors of the external conductors are isolated by separating plates.
  • Page 5: Set/Dm3Al Sensor

    If the sensor cable must be extended and there is a need for equipotential grounding, it should be done with the junction box LJB2. The cabling between the OilSET-1000 control unit and the junction box should be done with a shielded twisted pair instrument cable.
  • Page 6: Operation And Settings

    TEST FUNCTION Test function provides an artificial alarm, which can be used to test the function of the OilSET-1000 alarm device and the function of other equipment, which are connected to OilSET-1000 via its relays. Attention! Before pressing the Test button, make sure that the change...
  • Page 7: Factory Settings

    The device does not react to the test at all. Factory settings If the operation of OilSET-1000 is not as described in the previous chapter, check that the device settings are as in figure 7. Change the settings according to the following instructions if needed.
  • Page 8: Trouble-Shooting

    3.4 Connect the wire back to the connector. If the problem can not be solved with the above instructions, please contact Labkotec Oy’s local distributor or Labkotec Oy’s service. Attention! If the sensor is located in an explosive atmosphere, the multimeter must...
  • Page 9: Repair And Service

    In case of queries, please contact Labkotec Oy’s service. SAFETY INSTRUCTIONS OilSET-1000 control unit must not be installed in potentially explosive atmosphere. Sensors connected to it may be installed in zone 0, 1 or 2 potentially explosive atmospheres.
  • Page 10: Technical Data

    OilSET-1000 Oil Separator Alarm Device D15492AE-2 Installation and Operating Instructions TECHNICAL DATA SET/DM3AL sensor OilSET-1000 control unit Principle of operation Measurement of conductivity Dimensions 175 mm x 125 mm x 75 mm (L x H x D) Signal Analog 3 mA / 10 mA...
  • Page 11: Declaration Of Conformity

    DECLARATION OF CONFORMITY...
  • Page 12: Declaration Of Conformity

    DECLARATION OF CONFORMITY...
  • Page 13: Declaration Of Conformity

    DECLARATION OF CONFORMITY...

Table of Contents