• etc. = and so on order confirmation. These will remain valid at least until • s.a. = see also the agreed warranty period of the product has expired. • e.g. = for example Installation and operating instructions Wilo-Sub TWU 3..., TWU 3-...-P&P...
The advice on prevention. operator is responsible for ensuring that personnel fol- low these instructions and guidelines. WILO SE 10/2011 V4.1WE...
Page 7
Non-observance can result in injury or substan- meet the harmonized EU standards. Mobile radio tial material damage. 2.3 Directives used This product is subject • various EC directives • various harmonized standards • and various national standards. Installation and operating instructions Wilo-Sub TWU 3..., TWU 3-...-P&P...
Page 8
Caution: Wear ear protectors! In terms of the applicable laws and regulations, ear protection must be worn if the sound pres- sure is greater than 85 dB (A)! The operator is responsible for ensuring compliance with these regulations! WILO SE 10/2011 V4.1WE...
3 °C for up to 4 weeks. If longer storage is intended, the products should be emptied and dried out beforehand. Installation and operating instructions Wilo-Sub TWU 3..., TWU 3-...-P&P...
• Red LED lights up: Fault 4.2 Construction The unit was switched off by the automated control The Wilo-Sub TWU… is a floodable submersible motor mechanism (e.g. dry-run protection). The malfunction pump, which can be operated both vertically and hori- must be reset by pressing the RESET button zontally when immersed in a stationary installation.
• Switch box with capacitor, thermal motor protection 4.4.1 Operating mode “S1” (continuous operation) and on/off switch • Wilo pressure switching kit (0-10 bar), incl. 18 l dia- The pump can operate continuously at the rated load phragm expansion tank, manometer, shut-off device...
Page 12
(see the catalog and planning documents or con- and removal of the product. It must be possible to sult Wilo customer service for more information). reach the product safely in its operating and storage locations using the hoisting gear. The machine must be •...
Page 13
Remove the support clamp, feed the cable out which is already in place. Ensure that the discharge through the well cover and lower the cover on to the ports are level. well. Installation and operating instructions Wilo-Sub TWU 3..., TWU 3-...-P&P...
• Cable cross section 4 x 1.5 pumped liquid up to the top edge of the pump hous- ing. For optimum reliability, we recommend installing a Only slow-blow fuses or K characteristic automatic dry-run protection system. cut-outs may be used for pre-fusing. WILO SE 10/2011 V4.1WE...
5.6.5 Monitoring device connections between a pump stop and restart to allow the motor winding to cool down. The Wilo-Sub TWU series is not equipped with any • Never exceed the rated current on the motor. integrated monitoring devices. • Maximum voltage peak: 1000 V A motor protection switch must be set up at the •...
When using Wilo switching devices • All persons working on or with the product must have Wilo switching devices are designed so that the con- received, read and understood this operating and nected products are driven in the right direction. If the maintenance manual.
Page 17
The start pauses specified in the “Technical data” If no click is heard: chapter must be adhered to before starting up again. If Installation and operating instructions Wilo-Sub TWU 3..., TWU 3-...-P&P...
For shipping, the parts must be packed and sealed in checked and found to be in perfect working sufficiently large, non-tearing plastic sacks to prevent order. If it is not inspected, danger to personnel may result! WILO SE 10/2011 V4.1WE...
“Installation” chapter. The product must be • Ensure that all necessary tools and materials are avail- switched on as described in the “Start-up” chapter able. Tidiness and cleanliness guarantee safe and trou- Installation and operating instructions Wilo-Sub TWU 3..., TWU 3-...-P&P...
3 Impeller blocked or obstructed product faults, the following points must be observed • Switch off the unit, secure it against being switched in all cases: on again and free the impeller 4 Defective hose or pipeline WILO SE 10/2011 V4.1WE...
9.0.6 Further steps for troubleshooting If the points listed here do not rectify the fault, con- tact our customer service. They can help you as follows: • Telephone or written support from customer service Installation and operating instructions Wilo-Sub TWU 3..., TWU 3-...-P&P...
Si les gammes mentionnées ci-dessus sont modifiées sans notre approbation, cette déclaration perdra sa validité. Bevollmächtigter für die Zusammenstellung der technischen Unterlagen ist: WILO SE, Werk Hof Authorized representative for the completion of the technical documentation: Division Submersible & High Flow Pumps Mandataire pour le complément de la documentation technique est :...
Page 24
B'dan il-mezz, niddikjaraw li l-prodotti tas-serje jissodisfaw id- dispo izzjonijiet relevanti li ejjin: Makkinarju - Direttiva 2006/42/KE L-objettivi tas-sigurta tad-Direttiva dwar il-Vulta Baxx huma konformi WILO SE mal-Anness I, Nru 1.5.1 tad-Direttiva dwar il-Makkinarju 2006/42/KE. Nortkirchenstraße 100 44263 Dortmund Kompatibbiltà elettromanjetika - Direttiva 2004/108/KE...
Page 25
Si les gammes mentionnées ci-dessus sont modifiées sans notre approbation, cette déclaration perdra sa validité. Bevollmächtigter für die Zusammenstellung der technischen Unterlagen ist: WILO SE, Werk Hof Authorized representative for the completion of the technical documentation: Division Submersible & High Flow Pumps Mandataire pour le complément de la documentation technique est :...
Page 26
B'dan il-mezz, niddikjaraw li l-prodotti tas-serje jissodisfaw id- dispR izzjonijiet relevanti li ejjin: Makkinarju - Direttiva 2006/42/KE L-objettivi tas-sigurta tad-Direttiva dwar il-Vulta Baxx huma konformi WILO SE mal-Anness I, Nru 1.5.1 tad-Direttiva dwar il-Makkinarju 2006/42/KE.. Nortkirchenstraße 100 44263 Dortmund Kompatibbiltà elettromanjetika - Direttiva 2004/108/KE...
Page 27
T+ 54 11 4361 5929 wilo@wilo.hu Lebanon Saudi Arabia Czech Republic info@salmson.com.ar Taiwan WILO SALMSON WILO ME - Riyadh WILO Praha s.r.o. India WILO-EMU Taiwan Co. Ltd. Austria Lebanon Riyadh 11465 25101 Cestlice WILO India Mather and 110 Taipeh...
Page 28
Bau + Bergbau Kommune Österreich WILO SE Bau + Bergbau Zentrale Wiener Neudorf: Argentinien, Aserbaidschan, Nortkirchenstraße 100 WILO SE, Werk Hof Industrie WILO Pumpen Österreich GmbH Belarus, Belgien, Bulgarien, 44263 Dortmund Heimgartenstraße 1-3 Max Weishaupt Straße 1 China, Dänemark, Estland,...
Need help?
Do you have a question about the TWU 3 Series and is the answer not in the manual?
Questions and answers