Template
1-7/16
1-1/32
3/4
1/8
2-5/8
2-3/4
C L Spindle
Jamb
2-5/8 R.
Max.
1/8
2-5/8
Arm Plate
Provide
3/8" Dia.
Hole
1-1/16
(11/16 w/
Threshold)
2-3/4
1-25/32
1-1/4
1-19/32 1-13/32
2-3/32
1/4-20 x 1" FHMS
3-13/16
or #14 x 2" FWHS
ARM PLATE H
(4 Places)
Conversion from inches to metric: inch x 25.4.
Rixson Specialty Door Controls
®
Installation Instructions
7/8 Dia.
9/16
Finish Plate
1-1/4 Dia.
340 TOP PIVOT
Pivot Shown Engaged
Arm
19-1/4
10-3/4
7-7/16
Fasten Front
Mounting
Screws First
19-1/8
C L Spindle
3/16
11/32
1-7/32
5/8
29/32
50 (06-09)
1-15/32
15/32
21/32
9/32
1/4-20 x 5/8" FHMS or
#14 x 1/2" FHWS
1/16
1/4
5/8
Floor Plate
7/16
With Threshold
Use Top (2) Holes With Floor Plate
Use Bottom
(2) Holes
1-9/16
Cement Case
See
Tighten Spindle
Note 4
Screw Firmly
Washer
Spindle
Adapter
Spindle
www.rixson.com
50 Floor Closer
Single or Double Acting
6-3/4
9/32
JAMB PORTION
12-24 x 5/8" FHMS or
#12 x 1-1/4" FHWS
(2 Places)
1-1/8
DOOR PORTION
4-13/16
5-9/32
4-1/2
Floor
Plate
Cement Case
4-3/8
WITH FLOOR PLATE
Set Cement Case Flush
with Finished Floor
See Note 5
3/16
2
WITH THRESHOLD
Set Cement Case Flush
with Finished Floor
Notes:
1. Do not scale drawing.
2. Suitable reinforcing by others.
3. Rixson design threshold available on
request.
4. Tighten adjusting screw to notched "V"
Arm
line on arm to acquire standard initial
location of door. Screw moves door
towards and away from jamb to equalize
door clearances.
5. Provide 5/8" dia. holes for alignment
screws (2 places).
6. Do not remove grind plate until closer is
installed.
7. External stop by others required.
8. All dimensions given in inches.
866-474-9766 Technical Department
Center Hung
Non-Handed
9/32
1-5/16
9/32
1/4-20 x 5/8" FHMS or
#14 x 1-1/2" FHWS
(2 Places)
1-1/4
5/8
1-3/8" Min. Clearance
Required for Arm, Arm
Plate H and Shims
Door Mortised
1-9/16" Deep
for Arm
7/8
3/16
Door Mortised
A
B
Deep for Arm
1/4 Threshold
1-13/16
1-1/8
1/2 Threshold
1-9/16
7/8
See Note 5
B
A
3/16
Threshold

Advertisement

loading
Need help?

Need help?

Do you have a question about the ASSA ABLOY 50 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rixson ASSA ABLOY 50

  • Page 1 3/16 Notes: 1. Do not scale drawing. 11/32 2. Suitable reinforcing by others. 1-25/32 1-7/32 Tighten Spindle 3. Rixson design threshold available on Note 4 29/32 Screw Firmly request. 4. Tighten adjusting screw to notched “V” 1-1/4 Washer line on arm to acquire standard initial location of door.
  • Page 2 C. Case should be parallel with center line of door. D. CEMENT CASE SHOULD BE LEVEL. Place levels per Illustration. E. Grout in cement case with closer. Cement should not get between closer and case. Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department...
  • Page 3 If necessary, turn adjusting screw at bottom of heel edge of door to equalize side jamb clearances. G. Adjust arm alignment screws equally from each side Adjusting Screw center door in doorway. Alignment Screws Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department...
  • Page 4 RIXSON ® Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2005, 2009, Yale Security Inc., an ASSA ABLOY Group company. ASSA ABLOY All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
  • Page 5: Installation Instructions

    Notes: 1-3/8 Door 1. Do not scale drawing. 2. Suitable reinforcing by others. 9/16 3. Rixson design threshold available on request. 1-13/32 4. Tighten adjusting screw to notched “V” line 1-19/32 6-7/32 Spindle on arm to acquire standard initial location 10-1/2 of door.
  • Page 6 C. Case should be parallel with center line of door. D. CEMENT CASE SHOULD BE LEVEL. Place levels per Illustration. E. Grout in cement case with closer. Cement should not get between closer and case. Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department...
  • Page 7 If necessary, turn adjusting screw at bottom of heel edge of door to equalize side jamb clearances. G. Adjust arm alignment screws equally from each side Adjusting Screw center door in doorway. Alignment Screws Rixson Specialty Door Controls www.rixson.com 866-474-9766 Technical Department...
  • Page 8 RIXSON ® Rixson® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright© 2005, 2009, Yale Security Inc., an ASSA ABLOY Group company. ASSA ABLOY All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.