Fig. 5.
The detection area angle is 90°. The direction can be adjusted from
position A – G by rotating the detector´s plastic part. Each step is marked.
The detector lens covers a whole angle of 180° - therefore it does not
require any adjustment.
You can restrict the detection angle by adhesive masking strips
supplied with the package. This way you can eliminate problematic
parts of the detection area. The strips are to be stuck on the relevant
lens segment on the inside.
The PIR detection sensitivity can be configured by a 3-pole switch
located under the upper sensor. The letters correspond to sensitivity levels
as follows:
L
low – applicable to bad conditions
M medium
H high
Other
parameters
can
NORM
120s
N.C.
LED OFF
Antimasking OFF
Factory settings highlighted by bold letters.
The LED serves for PIR detector testing – checking the coverage. The
detector always sends information to the control panel. For normal detector
operation the LED should be turned off in order to save the battery.
The power save mode can be set up by DIP switch no. 2.
Testing (coverage test)
By DIP switch no. 1, enter test mode and by DIP switch no. 4 turn on the
LED indication. Close the detector.
protected area and immunity outside the protected area.
Bear in mind the potential changing of detecting distance influenced by
the environment.
Each movement is indicated by LED and it sends the information to the
control panel.
We recommend turning off the indication LED when the testing procedure
is finished. And set up the power save mode to 120s to get a longer battery
lifetime.
Normal operating mode
The detector sends a radio signal about activation when it is triggered. In
the case of tampering with the detector or tearing the detector off its
position the detector sends a tamper signal. Every 9 minutes a status report
is sent to the control panel to test that all its devices are present and ready
for operation.
Replacing the batteries
The detector checks its battery status automatically and if the batteries
are running low it informs the system. The detector remains fully functional.
The batteries should be changed as soon as possible (within 1 week).
Before battery replacement the control panel has to be switched to
service mode (see installation manual of the control panel) and then it is
possible to open the cover of the detector. Always use 3.6 V AA lithium
batteries.
Note: If you insert a nearly drained battery into the detector by mistake,
the detector does not start working and this status is indicated with the
transmitter LED flashing. If the battery is completely drained, the detector
does not react at all.
Caution: Expired batteries should not be thrown into the garbage, but
disposed of according to local regulations.
The JA-89P wireless outdoor PIR detector
The JA-89P wireless outdoor PIR detector
be
configured
using
a
DIP
TEST
5s
N.O.
LED ON
Antimasking ON
Test the detection range of the
Problem
The detector
makes false
intrusion
alarms
Occasionally
no reaction
to
movement
Detector
ignores any
movements
switch:
5 s ... šetřící režim
on
Fig. 6. Detector dimensions (mm)
Power
Average battery lifetime
Communication band
RF range – communication range
Optex detector parameters
Detection characteristics
Recommended installation height
Object motion speed
Battery saving timer
LED indication
Operational environment according to EN 50131-1
Security grade
Operating temperature range
Detector cover conformance
Max. relative humidity of the environment
Dimensions
Weight
Complies with
Can be operated according to
2 / 2
Troubleshooting
Problem cause
Solution
Lower detection area is
Set the detection area
unnecessarily long.
properly.
The detector is exposed
Remove the reflector, mask
to direct/reflected light
the area exposed to the
(sun light, car light etc.).
reflection of light or change
the detector position.
There is a moving object
Remove the moving object or
in the area (laundry on
change the detector position.
the clothes-line, plants
Or put the stickers on part of
etc.).
the lens to avoid detection in
a problematical place.
Lower detection area is
Set the detection area
unnecessarily short
properly
Sensitivity is set to low
Change sensitivity to medium
(L).
(M) or high (H).
The detector is in battery-
While testing operation, set
save mode
the battery-save timer to 5
seconds.
Low battery
Replace the battery
LED indicator lights but
The control panel is out of
there is no reaction in the
range, check the battery, try
control panel.
to reposition detector or
control panel
Technical specifications
Lithium battery type CR14500 (AA) 3,6 V / 2,45 Ah
(valid for enabled 120s saving mode)
Please note: Batteries are not included
ETSI EN 300 220-1, EN 50130-4,
EN 55022, EN 60950-1, EN 50581
JABLOTRON ALARMS a.s. hereby declares that the JA-89P
is in a compliance with the relevant Union harmonisation
legislation:
Directives
No:
2014/53/EU,
2014/30/EU, 2011/65/EU. The original of the conformity
assessment can be found at www.jablotron.com - Section
Downloads.
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer
or directly to the producer after use.
approx. 3 years
868.5 MHz
up to 300 m (open area)
12 m / 90°; 16 segments
0.8 – 1.2 m
-1
0.3 – 1.5 ms
adjustable 5 s or 120 s
during a coverage test
IV
according to Optex
-20 °C to +60 °C
IP55
95 %
186 x 71.3 x 105.5 mm
500 g
ERC REC 70-03
2014/35/EU,
MKU51105

Advertisement