Installing the cooling unit
It is important to select the proper location for setting up the unit. To ensure
trouble-free operation, please note the following points:
 Set up the cooling unit in a dry, sheltered place. Avoid placing it near heat
sources such as radiators, gas ovens or hot water pipes. Do not place in
direct sunlight.
 On a boat, install the cooling unit, if possible, below the waterline.
 The heated air must dissipate unhindered (fig. e, page 8).
 When installing the cooling unit in a closed room such as a wardrobe,
pantry or aft compartment, openings must have a cross section of at
least 200 cm² (25 cm x 8 cm) for cooling and exhaust air.
 Make sure that the air flow on the condenser (fig. e 3, page 8) is not
restricted.
 Maintain a minimum distance between the condenser and adjoining wall
of 50 mm.
 CS-NC15: Observe the drilling template (fig. l, page 11) and the
installation drawing (fig. m, page 12).
6.3
Installing the external temperature regulator
Mechanical thermostat
The temperature regulator can be mounted either on the outside or inside of
the cooling container. The interior temperature is regulated depending on the
surface temperature of the vaporiser, or for VD-14N and VD-15, depending
on the room temperature.
➤ Connect the coiled end of the sensor cable to the vaporiser (not VD-14N,
VD-15) using the clamping plate. This is premounted on VD-14N, VD-15.
➤ Make sure that the sensor line does not make contact anywhere else with
the vaporiser or with the suction line.
TEC control
The TEC control must be attached outside of the cooling container.
The internal temperature is regulated according to the vaporiser surface
temperature.
The temperature sensor has been factory-mounted to the accumulator.
➤ Connect the temperature sensor with the TEC control via the plug-in
coupling.