Rheem Raypak R207A Installation And Operation Manual page 33

Gas-fired pool and spa heater, low nox models
Table of Contents

Advertisement

Desooting Procedure
WARNING: Soot Is Combustible. Exercise Extreme
A
Care.
Soot will clog areas between fins and cause eventual
tube failure. Any sign of soot at the base of the burners or
around the outer jacket indicates a need for cleaning.
1. Remove top and flue collector from cabinet.
2. Remove "V" baffles from heat exchanger.
3. Remove burner tray. See page 31.
4. Remove ProTek Shield Assy bonding wire from heat
exchanger stud.
5. Remove heat exchanger from the heater and wash
with a garden hose, making sure soot is removed
from spaces between fins.
6. Reverse above procedure to reinstall.
NOTE: In extreme cases it may be necessary to do
steam cleaning at the local car wash. DO NOT WIRE
BRUSH.
Combustion Chamber Removal
To remove combustion chamber, you must first have
removed the heat exchanger.
Figure 58. Refractory Panels
WARNING: When removing the burners or heat
A
exchangers, take precautions to avoid creating airborne
dust and avoid inhaling airborne fibers. When cleaning
spills, use wet sweeping or High Efficiency Particulate
Air (HEPA) filtered vacuum to minimize airborne dust.
Use feasible engineering controls such as local exhaust
ventilation or dust collecting systems to minimize
airborne dust. Wear appropriate personal protective
equipment including gloves, safety glasses with side
shields, and appropriate NIOSH certified respiratory
protection, to avoid inhalation of airborne dust and
airborne fiber particles.
Unitherm Governor (U.G.) Replacement
1. Shut water, gas and electricity off, close valves and
relieve pressure.
2. Drain heat exchanger.
3. Remove retainer plug located next to the outlet pipe
4. Unsnap old U.G. to remove from retainer plug. Snap
5. Reinstall retainer plug, taking care to lubricate
Figure 59. Unitherm Governor – Polymer
To test the operation of the Unitherm Governor, place in
hot water (over 110°F [43°C]) and watch for movement
against spring. If there is no movement, replace unit.
F10724
Figure 60. Unitherm Governor/Bypass Valve Assy – ASME
connection on polymer header models.
in new U.G.
gasket with a non-petroleum based grease such as
AquaLube.
UG PLUG
UNITHERM GOVERNOR
GASKET
UNITHERM
GOVERNOR
NOTE: The U.G. on brass header models (ASME)
can only be replaced by replacing the entire Unitherm
Governor/Bypass Valve Assembly.
F10725
UG/BYPASS ASSY
F10642-2
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Raypak r337aRaypak r267aRaypak r407a

Table of Contents