Page 1
PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE USER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL. THERMO PRODUCTS, LLC. PO BOX 217 NORTH JUDSON, IN 46366...
The predetermined limit locations on all of the Thermo Pride oil fired furnaces have been tested and approved by Thermo Products, LLC. Any attempt to relocate these safety controls or replace these safety controls with a control that is not approved, or is incompatible, may result in personal injury, substantial property damage or death.
SECTION I. SAFETY SECTION II. GENERAL INSTRUCTIONS A. VENTING B. DRAFT REGULATORS C. DUCT WORK/AIR CONDITIONING D. FILTERS MOUNTED EXTERNAL TO FURNACE E. LIMIT POSITION AND LOCATION F. BURNER INSTALLATION G. BURNER SPECIFICATIONS AND APPLICATIONS H. HEAT EXCHANGER CLEANING INSTRUCTIONS III.
All installations and services must be performed by qualified service personnel. II. GENERAL INSTRUCTIONS - READ BEFORE START OF INSTALLATION 1. The heating output capacity of the furnace proposed for installation should be based on a heat loss calculation made according to the manuals provided by the Air Conditioning Contractors of America (ACCA) or the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc.
90 deg. elbow and rotate it 90° counterclockwise. Then, remove knock-out in side casing and extend vent through the opening. A trim collar may be ordered from Thermo Products to hide the gap around the flue pipe. This trim collar, however, is not required for operation. Trim collar/gasket part numbers(s) 14121 / 330073.
All installations and services must be performed by qualified service personnel. B. DRAFT REGULATORS: A draft regulator is supplied with the furnace and should be installed according to the regulator manufacturers recommendations. With the burner operating, use a draft gauge to adjust the regulator to the proper setting. (refer to the instructions enclosed with draft regulator to adjust to the proper setting).
The predetermined limit locations on all of the Thermo Pride oil fired furnaces have been tested and approved by Thermo Products, LLC. Any attempt to relocate these safety controls or replace these safety controls with a control that is not approved, or is incompatible, may result in personal injury, substantial property damage or death.
All installations and services must be performed by qualified service personnel. F. BURNER INSTALLATION: NOTICE: Remove all cardboard packing from around chamber before installing burner. The oil burner will mount on three stud mounting bolts on the lower mounting plate covering the opening in the front of the heat exchanger.
AN 80° SPRAY ANGLE AND A HOLLOW SPRAY PATTERN WOULD BE ABBREVIATED IN THE TABLE AS “0.65 X 80 ° H”. For more specific burner information, contact Thermo Products, LLC. P.O. Box 217, North Judson, IN 46366. Phone 574-896-2133. OIL NOZZLE CAPACITY CHART NOZZLE SIZE...
All installations and services must be performed by qualified service personnel. H. HEAT EXCHANGER CLEANING INSTRUCTIONS: cWARNING: THE HEAT EXCHANGER MUST BE CLEANED BY A QUALIFIED SERVICE PERSON. It is important to inspect and clean the heat exchanger once a year, or as necessary, to remove any build-up of soot. A layer of soot on the inside of the heat exchanger will act as an insulator and reduce heat transfer, resulting in less efficiency.
III. USERS INFORMATION SECTION A. OIL SUPPLY: Do not allow the fuel tank to run completely empty. During the summer, keep the tank full to prevent condensation of moisture on the inside surface of the tank. If the fuel tank runs completely dry, it may be necessary to purge the lines of trapped air.
All installations and services must be performed by qualified service personnel. E. FILTER CLEANING AND LOCATION: The air filters should be inspected each month and cleaned when dirty. Cleaning the air filters frequently may reduce airborne contaminants from entering the furnace and depositing in the furnace, duct system and home. cWARNING: To avoid injury from moving parts, hot surfaces, or electrical shock, shut off the power to the furnace before removing any furnace access doors to service the air filters.
Page 13
COMBUSTION AND EFFICIENCY TESTING FOR THERMO PRIDE OIL FIRED CENTRAL FURNACES. Complete this form for each Thermo Pride furnace installed. Read instruction manual carefully before making tests. Retain this form with furnace. CUSTOMER NAME ADDRESS CITY, STATE BURNER MODEL NO. HEATING SYSTEM COMBUSTION CHAMBER...