MODEL
HEAT INPUT RATE (BTUH)
HEATING CAPACITY (BTUH)
BURNER NOZZLE (GPH X
ANGLE, HOLLOW CONE)
BURNER ORIFICE-NAT. GAS
BURNER ORIFICE-PROP. GAS
OIL PUMP PRESSURE (PSIG)
GAS SUPPLY PRESSURE (IN.W.G.)
MINIMUM REQUIRED
PROPANE
NATURAL
MAXIMUM ALLOWED
PROPANE
NATURAL
GAS MANIFOLD PRESSURE (IN. W.G.)
PROPANE
NATURAL
VENT PIPE SIZE (INCHES)
DESIGN TEMPERATURE RISE (°F)
SEASONAL EFFICIENCY
(AFUE*, %)
*AFUE - INCLUDES STEADY STATE THERMAL EFFICIENCY AND OFF CYCLE
LOSSES.
ELECTRICAL RATINGS AND SETTINGS:
ELECTRICAL SUPPLY: 120 VAC / 60HZ / 1 PHASE
MAXIMUM TIME DELAY TYPE FUSE OR HACR BREAKER RATING: 15 AMPS
TOTAL RATED CURRENT (AMPS): 11.3 (OMC), 6.81 (GMC)
NOMINAL HEAT ANTICIPATOR SETTING -- 0.2 mA (OMC), 0.8 mA (GMC)
DIMENSIONS & WEIGHTS:
CABINET: WIDTH - 18 IN., DEPTH - 24 IN., HEIGHT - 57 IN.
NO.70 MOBILE HOME BASE: WIDTH - 18 5/16 IN., DEPTH - 24¼ IN., HEIGHT - 4 IN.
WARM AIR DUCT: WIDTH – 12 IN., DEPTH – 12 IN., HEIGHT - 14 ¼ IN.
COTTAGE BASE: WIDTH – 18 3/16 IN., DEPTH - 24¼ IN., HEIGHT – 14¾ IN.
FILTER QUANTITY & SIZE: (2) @ 17 ¾ IN. x 13 ¾ IN. x 1 IN. EA.
APPROXIMATE SHIPPING WEIGHT: 240 LBS.
PRODUCT LISTED UNDER UL FILE NUMBER -- MP3241

III. FURNACE SPECIFICATIONS

OMC-70
85,000
71,000
0.65X80A
---------
---------
100
---------
---------
---------
---------
---------
---------
4
85
84
9
GMC-85
85,000
69,700
-------
#17 DMS
#36 DMS
-------
11
4.5
13.9
13.9
10 + 0.3
3.5 + 0.3
4
85
82