Configuration with the NCTerminal Software
Camera 1: The output is activated when a camera is connected.
Example: Switching on the power supply of a connected camera.
Local or remote alarm input: The status of the input is looped
through to an output.
Example: Connection of a buzzer that follows an external sensor.
This means that inputs and outputs of a VideoJet X.21/G.703
<-> VideoJet X.21/G.703 connection can also be crossed so
that the relay follows the input of the remote end.
Alarm sources: In addition to the alarm input mentioned above,
internal alarm sources (video alarm, motion detection) are available
for switching the outputs.
Example: Connection of external signalling for motion detection.
In the second column, the response of each input on disconnection
can be configured. States defined here have priority over all other
existing states once the connection has been terminated. If, for
example, an activated output is operated in monostable mode (see
section below), termination of a connection ends activation of the
output before the time constant has elapsed. The definition of idle
state and active state is given in the next section.