Technical Specifications; Mounting; Commissioning; Servicing - Bartec 07-4602-1 12 Series Instructions For Use Manual

Ex-signal horn
Table of Contents

Advertisement

Available languages

Available languages

5

Technical specifications

5.1
General data
Material
Dimensions
Weight
Sound pressure
Temperature range
Duty cycle
Protection type according to IEC 60529
Explosion protection for gas
Explosion protection for dust
Test certificate
5.2
Electrical data
Type
Rated current
07-4602-1112
24 V=
07-4602-1212
24 V~, 50 Hz
07-4602-1312
42 V - 48 V~, 50 Hz
07-4602-1412
115 V~, 50/60 Hz
120 V~, 60 Hz
07-4602-1512
230 V~, 50 Hz
6

Mounting

For dimensions and mounting see "Zeichnungen / Drawings / Dessins"
page 11.
7

Commissioning

Before commissioning make sure that:
• the appliance has been mounted according to instructions,
• the electrical connections have been carried out correctly,
• the right fuse in accordance with 5.2 has been installed,
• the appliance is not damaged in any way.
8

Servicing

The appliance is maintenance-free
9

Cleaning

Zone 1:
• Clean only with a damp cloth using water or mild non-chafing, non-
scratching cleaning fluid. Never use aggressive substances or solvents
when cleaning.
Zone 21:
• Clean with a cloth, brush, vacuum-cleaner or similar. For wet cleaning use
water or mild non-chafing, non-scratching cleaning fluid. Never use
PC, black
178 mm x 207 mm x 104 mm
1500 g
max. 105 dB
-40 °C ... + 50 °C
70%
IP 65
II 2G Ex e mb IIC T5 Gb
II 2D Ex tb IIIC T70°C Db
BVS 05 ATEX E 113X
Voltage range
Current
consumption
21,6 ... 26,4 V
350 mA
21,6 ... 26,4 V
450 mA
37,8 ... 52,8 V
220 mA
102,5 ... 126,5 V
205 mA
108 ... 131 V
220 mA
208 ... 250 V
70 mA
Technical specifications
Fuse to be
connected in series
F 0,5 A
F 0,63 A
F 0,315 A
F 0,315 A
F 0,125 A
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents