07/04 AWB2724-1490GB
A
Think future. Switch to green.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Teleservice XC100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Moeller Teleservice XC100

  • Page 1 Building Automation Industrial Automation Systems Hardware, Engineering, Configuration Teleservice XC100 07/04 AWB2724-1490GB Think future. Switch to green.
  • Page 2 No part of this manual may be reproduced in any form (printed, photocopy, microfilm or any other process) or processed, duplicated or distributed by means of electronic systems without written permission of Moeller GmbH, Bonn. Subject to alteration without notice.
  • Page 3 Warning! Dangerous electrical voltage! Before commencing the installation • Disconnect the power supply of the device. • Suitable safety hardware and software measures should be implemented for the • Ensure that devices cannot be accidentally I/O interface so that a line or wire breakage restarted.
  • Page 4 • Measures should be taken to ensure the • Wherever faults in the automation system proper restart of programs interrupted may cause damage to persons or property, after a voltage dip or failure. This should external measures must be implemented to not cause dangerous operating states even ensure a safe operating state in the event for a short time.
  • Page 5: Table Of Contents

    07/04 AWB2724-1490GB Contents About this manual List of revisions Structure Abbreviations and symbols Further documentation General Range of applications Hardware/Software requirements XC100/X200 – PC Connection Physical structure of the connection (overview) Connection PC – modem or modem – XC100/XC200 Connection PC – TD32B modem –...
  • Page 6 07/04 AWB2724-1490GB...
  • Page 7: List Of Revisions

    These manuals are available as online PDF files, with the exception of the installation instruction from Messrs. Westermo which is supplied on a CD. The most current and up-to-date edition of the manual can also be found under http://www.moeller.net/support: search term: e.g. “AWB2725-1452G”.
  • Page 8 07/04 AWB2724-1490GB...
  • Page 9: Range Of Applications

    07/04 AWB2724-1490GB 1 General Range of applications Hardware/Software requirements The telecontrol service for XC100/XC200 is intended for use • Hardware wherever PC and XC100/XC200 controller are at different – Programming PC locations, and the connection therefore has to be established via –...
  • Page 10 07/04 AWB2724-1490GB...
  • Page 11: Physical Structure Of The Connection (Overview)

    07/04 AWB2724-1490GB 2 XC100/X200 – PC Connection Physical structure of the connection (overview) Connection PC – modem or modem – XC100/XC200 The following diagram shows how the XC100/XC200 is connected Data transfer is asynchronous, handshake signals are not used. For with the PC.
  • Page 12: Modem Td32B - Xc100/Xc200 Connection

    07/04 AWB2724-1490GB XC100/X200 – PC Connection Modem TD32B – XC100/XC200 connection Connection modem – modem Cable layout Telecontrol cable connection figure 3 shows the necessary connection between the RS-232 The connection between the two modems is made via the public interface on the XC100/XC200 and the RS-232 interface on the and/or private telephone network.
  • Page 13: Connection Via 2-/4-Wire Leased Line

    07/04 AWB2724-1490GB Connection modem – modem Connection via 2-/4-wire leased line Connection via dial-up line The following diagrams show the telecontrol connection via the The following diagram shows the telecontrol connection via the terminal block on the left at the bottom of the modem or at the terminal block on the left at the bottom of the modem or at the RJ-12 connector.
  • Page 14: Modem Settings

    07/04 AWB2724-1490GB XC100/X200 – PC Connection Modem settings The modem settings for leased line or dial-up line connections are made using the DIP switches. Note! Switch Off the power supply before adjusting the DIP switches and make sure that you adhere to the protective measures against electrostatic charging! The DIP switches can be found under the cover at the top of the modem.
  • Page 15 07/04 AWB2724-1490GB Modem settings Table 3: DIP switch SW 3: Settings for dial-up line DIP switch SW 3 Modem settings Description Modem settings PC end XC100/200 end 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 0 x x x x x x x 4-wire connection 0 x x x x x x x x x x x x x x 2-wire connection...
  • Page 16: Leased Line

    07/04 AWB2724-1490GB XC100/X200 – PC Connection Table 5: DIP switch SW 5: Settings for dial-up line DIP switch SW 5 Modem settings Description Modem settings PC end XC100/200 end 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 0 0 0 0 x x x x Use saved parameters 0 0 0 0 x x x x 0 0 0 x x x x V.21,...
  • Page 17: Led Status Indication

    07/04 AWB2724-1490GB LED status indication LED status indication Full intensity The modem is in normal operation Half intensity The modem is in test mode Flashing, with click in Voltage supply problems the loudspeaker Flashing with 1 : 6 RAM defective (ON : OFF) ON/OFF, with click in Modem unable to start...
  • Page 18 07/04 AWB2724-1490GB...
  • Page 19: Modem Connection Via Leased And Dial-Up Lines

    07/04 AWB2724-1490GB 3 Programming A simple user program (counter function with LED display) serves as an example. Modem connection via leased and dial-up lines The communication connection between the two modems is established via a leased or dial-up line. The following illustration takes consideration of both of these connection types.
  • Page 20: Connection Between Pc And Control

    07/04 AWB2724-1490GB Programming Connection between PC and control Once the compiled program is present and the communication parameters are set, establish the connection between the programming PC and the PLC via ‹Online – Log-in›. Load the user program into the PLC with the “Log-in” command.
  • Page 21 07/04 AWB2724-1490GB Index Numerics Establish connection between PC and control ..16 2-wire leased line ......9 4-wire leased line .