Matsutec HA-102 Instructions Manual

Matsutec HA-102 Instructions Manual

Ais configuration
Hide thumbs Also See for HA-102:

Advertisement

Instructions for Matsutec AIS Configuration

1. Requirements

a. Matsutec AIS device, model HA-102
b. Computer (OS Windows)
c. Power and data cable
d. Application software HA_CONFIG.exe

2. Procedure

2.1 Connect the Matsutec AIS device with the computer.
Connect AIS RS232 port directly to the DB9 of the computer or by an adapter of
RS232-to-USB to the USB port of the computer.
Note:
When with a USB adapter, please make sure to install the USB driver of the adapter
firstly.
2.2 Power on the AIS device.

Advertisement

Table of Contents
loading

Summary of Contents for Matsutec HA-102

  • Page 1 Power and data cable d. Application software HA_CONFIG.exe 2. Procedure 2.1 Connect the Matsutec AIS device with the computer. Connect AIS RS232 port directly to the DB9 of the computer or by an adapter of RS232-to-USB to the USB port of the computer.
  • Page 2 2.3 Run the application HA_CONFIG.exe. Below shows the illustration and definition.
  • Page 3 Definitions: 1. Communication COM The Com port on the computer that is to communicate with the AIS device 2. Communication baud rate The baud rate of the com port to communicate with the AIS device 3. Connect /disconnect button Click to switch between com port connect and disconnect. 4.
  • Page 4 2.4 Select the correct com port that the AIS device is connected with. Note: When with a USB adapter, you can get the correct com port number from the com port property of the device manager. Use the default baud rate 38400bps.
  • Page 5 2.5 Click the [Connect] button on the right side to setup a connection between the application and the AIS device. It will return “Connect Device Success” and update the current static configuration of the AIS device.
  • Page 6 2.6 Edit the static data , make it of your own ship. Changed items will show in color BLUE. 2.7 Click the [Save Data to Device] button to program the AIS device. For model HA-102, it will return “Save Data Success” and update the current static configuration of the AIS device.
  • Page 8 2.8 Click the [Read Data From Device] button to get the current configuration. It will return “Read Data Success” and update the current static configuration of the AIS device.
  • Page 9 Appendix 1 Troubleshooting Type Symptom Remedy COM Port Error The port is not recognized or could not be used. This fault is normally irrelevant to the AIS device. Check the computer port connection. Communication Communication fails. Fails 1. AIS device power on? 2.