Download Print this page
Yale UniTrol UNI-50BC Series Installation Instructions
Yale UniTrol UNI-50BC Series Installation Instructions

Yale UniTrol UNI-50BC Series Installation Instructions

Advertisement

Quick Links

®
UniTrol Door Controls
UNI-50BC Series
Sized Closers
UNI-51(BF) Series
Multi-Sized Closers
"DL" suffix (Delayed Action) is an optional feature. A separate instruction
packed with these instructions, showing valve locations and adjustment procedures
Standard Frame
Installation
1-7/8 to 4-5/8
Frame Reveals
(Uses 6190 Bracket).
Bracket illustration page 4.
See Page 2
Deep Frame
Installation
Frame Reveals Over 4-5/8
(Uses 6191 Clamp Kit).
Bracket illustration page 4.
See Page 3
Flush Transom
Installation
Flush Partitions
(Uses 589L Bracket).
Bracket illustration page 4.
See Page 4
NOTE:
For special applications a separate door and frame preparation template is packed with these instructions
Use this instruction sheet for installation sequence and closer adjustments only
• It is recommended that the door on which the door closer will be installed be hung on ball bearing hinges. Door must swing freely
• Door and Frame must be properly reinforced, or use of special fasteners employed, to prevent the mounting screws from pulling out.
• All dimensions are given in inches with corresponding metric dimensions (mm) in parenthesis.
Components:
Power Adjustment Screw
(1/8 Hex Drive)
51, 51BF Only
"BC" Valve
4
Closer
Size
Stamp
Pinion Cap
Installation Instructions
An incorrectly installed or improperly
adjusted door closer can cause
property damage or personal injury.
These instructions should be followed
to avoid the possibility of misapplication
or misadjustment.
Right Hand Door - RH
Left Hand Reverse - LHR
Right Hand Door - RH
Left Hand Reverse - LHR
Right Hand Door - RH
Left Hand Reverse - LHR
UniTrol Parallel
Arm Assembly
Soffit Plate
Main Arm
Hold-Open Option
"L"Valve
80-9350-2514-010 (07-09)
will be
.
Arm Identification
Door Width
28" - 32"
(0.70 - 0.80m)
33" - 41"
(0.85 - 1.00m)
Optional
Cover
42" - 48"
50P
(1.05 - 1.20m)
"S"Valve
Non Hold Open (UL Listed)
Hold Open (H) (Not UL Listed)
Models:
Sized
Multi-Sized
(Sizes 2, 3, 4, 5, 6)
(Sizes 3 thru 6)
UNI-52BC(H)
UNI-51BF(H)
UNI-53BC(H)
UNI-54BC(H)
(Sizes 1 thru 4)
UNI-55BC(H)
UNI-51(H)
UNI-56BC(H)
Left Hand Door - LH
Right Hand Reverse - RHR
Left Hand Door - LH
Right Hand Reverse - RHR
Left Hand Door - LH
Right Hand Reverse - RHR
Arm Stamping
Non Hold Open
Main Arm
9-1/2"
6100-11
(241mm)
11"
6100-13
(279mm)
12-1/2"
6100-14
(318mm)
Hold Open
6100-1
6100-3
6100-4
Page 1

Advertisement

loading

Summary of Contents for Yale UniTrol UNI-50BC Series

  • Page 1 Installation Instructions Non Hold Open (UL Listed) Hold Open (H) (Not UL Listed) 80-9350-2514-010 (07-09) ® UniTrol Door Controls Models: An incorrectly installed or improperly UNI-50BC Series Sized Multi-Sized Sized Closers adjusted door closer can cause property damage or personal injury. (Sizes 2, 3, 4, 5, 6) (Sizes 3 thru 6) UNI-51(BF) Series...
  • Page 2 Door Template Typical for All Installations Template Information Fr me Template for 1-7/8 to 4-5/8 Reveals • Door template is typical for all installations. • Frame template must be selected according to frame reveal: 2-3/4 (69.9) Frame Template at right (9.5) Frame Reveals 1-7/8 (48) to 4-5/8 (117).
  • Page 3 Frame Template for Reveals Over 4-5/8 Typical Installation Door Template on Page 2 Left Hand Door 2-3/4 “S” and “L” Valves (69.9) (9.5) 5/16 4-3/8 (50.8) Reveal (111) Pinion Flat 7/16 Right Hand Door (11.1) “S” and “L” Valves 6191 Clamp Kit Hinge 5/16 2-1/8...
  • Page 4 Yale ® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. 6=56BC Code Code Copyright © 1999, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Page 4 Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.

This manual is also suitable for:

Unitrol uni-51(bf) seriesUni-52bc(h)Uni-54bc(h)Uni-53bc(h)Uni-55bc(h)Uni-51bf(h) ... Show all