Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
67411055-A
®
SPRINT
Barriera oleodinamica
H
ydraulic
Barrière oleodynamique
Barrera
SEA S.p.A.
Zona Ind.le S. Atto - 64020 S. Nicolò a Tordino (TE)
Tel. 0861.588341 - Fax 0861.588344
Numero Verde: 800.979.732
www.seateam.com
e-mail: seacom@seateam.com
Rev. 01 - 03/2016
barrier
oleodinámica
Italiano
English
Français
Español
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Sprint and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SEA Sprint

  • Page 1 ® Sistemi Elettronici di Apertura Porte e Cancelli Italiano International registered trademark n. 804888 English Français SPRINT Español Barriera oleodinamica ydraulic barrier Barrière oleodynamique Barrera oleodinámica SEA S.p.A. Zona Ind.le S. Atto - 64020 S. Nicolò a Tordino (TE) Tel. 0861.588341 - Fax 0861.588344 Numero Verde: 800.979.732...
  • Page 2 7 Foundation plate out of galvanized steel 8 24V - 1400 rpm electric motor 9 Cataphoresis-treated and polyester painted SPRINT casing, for outside, protects all included mechanical and electronic devices from fire, flood, lightning, etc. Predisposed for the application of photocells, key switch, proximity reader.
  • Page 3: Installation Instructions

    Electronic equipment User 1 24V DG R1 Gate 1 DG R1 Note: The frequency of use is valid only for the first hour at 20°C room temperature. SPEED BEAMS (For SPRINT 24V only) Overall dimensions: Beam Length Opening time Speed setting Beam 3 m 6’’...
  • Page 4 ® Sistemi Elettronici di Apertura Porte e Cancelli English 2) Foundation plate anchoring Make a 500 x 500 x 300 mm (depth) hole in the ground. Fill the hole with R425 concrete and place the foundation plate as shown in Fig.
  • Page 5 ® Sistemi Elettronici di Apertura Porte e Cancelli English 4) Mounting of the spring N.B.: The operator comes as shown in Fig.1 (opening on the left). Example: Barrier with opening on the left (Fig.1) Barrier with opening on the right (Fig. 2) Before installing the spring check the choice of the barrier, if right or left hand side.
  • Page 6 ® Sistemi Elettronici di Apertura Porte e Cancelli English 5) Mounting of the Light beam Note: For 4 and 5 m beams it is recommended to use the fork support or the flexible support. Fixing Led profile Joint Led profile Anti-blunt rubber 5 mm Fig.
  • Page 7 ® Sistemi Elettronici di Apertura Porte e Cancelli English 6) Skirt mounting on the beam Fig.12...
  • Page 8 ® Sistemi Elettronici di Apertura Porte e Cancelli English 7) Beam balancing Release the beam with manual release, so that it is free to be opened and closed manually (Fig.13). Place the beam at approx. 45°. Loosen or tighten the spring stretching nut until the spring counterbalances the weight of the 45°...
  • Page 9 ® Sistemi Elettronici di Apertura Porte e Cancelli English ONLY 230V VERSION 9) Force adjustment If necessary the piston force can be adjusted by the two adjusting screws (grey and yellow) placed on the front lower place of the Hydraulic pump unit (Fig. 15). * The automation is adjusted at 15 Kg force ex works so to guarantee the anti-crush safety.
  • Page 10 ® Sistemi Elettronici di Apertura Porte e Cancelli English 10) Drilling scheme for passage of light power cable Fig.17 Use hole A for assembly of the right beam. Use hole B for assembly of the left beam. Right beam Left beam Fig.18 Fig.19 When mounting the...
  • Page 11 Fig. 20 sketches the electrical system that the barrier requires. The two numbers located near the electrical cables indicate the cable number and section. Captions: 1- SPRINT electronic control unit + Plug-in receiver 2- Transmitting photocell 3- Receiving photocell 4- Key switch...
  • Page 12: Periodical Maintenance

    NOTE: THE MANUFACTURER SHALL NOT SHOULDER ANY RESPONSIBILITIES IN CASE OF DAMAGE CAUSED BY INAPPROPRIATE, WRONG OR CARELESS USE. SEA reserves the right to make all the necessary changes and modifications of the products and / or manuals without giving prior notice.
  • Page 13 SEA. 4) PAGAMENTI Le forme di pagamento ammesse sono quelle comunicate o accettate di volta in volta dalla SEA. Il tasso di interesse sul ritardo da pagamento è del 1,5% mensile e comunque non oltre il tasso massimo legalmente consentito.
  • Page 14 The recognized defects, whatever their nature, shall not produce any responsibility and/or damage claim on the part of the Buyer against SEA. The guarantee is in no case recognized if changes are made to the goods, or in the case of improper use, or in the case of tampering or improper assembly, or if the label affixed by the manufacturer has been removed including the SEA registered trademark No.
  • Page 15 14. Transit through the leaves is allowed only when the gate is fully open. 15. The User must not attempt to repair or to take direct action on the system and must solely contact qualified SEA personnel or SEA service centers. User can apply only the manual function of emergency.
  • Page 16 3. Este producto fue diseñado y construido exclusivamente para el uso especificado en esta documentación. Cualquier otro uso no expresamente indicado puede afectar la integridad del producto y ser una fuente de peligro. El uso inadecuado es también causa de anulación de la garantía. SEA S.p.A. se exime de toda responsabilidad causadas por uso inapropiado o diferente de aquel para el que el sistema automatizado fue producido.
  • Page 17 N.B: L’estensione della garanzia legale di 12 mesi a 24 mesi e 36 mesi è va- lida solo se il presente modulo viene rispedito per posta o fax a SEA S.p.A. entro 15gg dalla data di acquisto. Allegare relativa fattura d’acquisto.
  • Page 18 è stato testato singolarmente al fine di garantire i più alti livelli qualitativi e la vostra soddisfazione. Vi ringraziamo per aver scelto SEA. This item has been produced following strict production procedures and has been singularly tested for the highest quality levels and for your complete satisfaction.
  • Page 20 ® Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 SEA S.p.A. Zona industriale 64020 S.ATTO Teramo - (ITALY) Tel. +39 0861 588341 r.a. Fax +39 0861 588344 www.seateam.com seacom@seateam.com...