POWERING THE WALK-TESTER
Before installation, remove the battery compartment
cover (fig. 3 and fig. 4) and insert a 9V battery
(PP3). Make sure the on/off switch on the
is set to `off' while connecting the battery (fig. 5).
Fig.3. Removing battery
compartment cover
Fig.5. On / Off switch
INSTALLING THE WALK-TESTER
1. Remove the cover from the detector housing by
loosening the stainless-steel screw at the bottom
of the detector (fig. 6) to access the detector's
programming button (fig. 7).
2. Enter the detector into `walk-test' mode by
pressing the program button once (fig. 7). The
detector's LED will flash out its current settings.
Wait for the flashing to complete. The detector is now
in `walk-test' mode for five minutes after the last
detection. After that, it will revert to normal mode.
3. Walk-test mode can be cancelled at any time by
pressing the detector's programming button twice.
Fig.6. Detector's cover and screw
Fig.7. Detector's programming button
Rev Date: 08/19
Walk-Tester
Fig.4. PP3 battery
connector
Quick Start Guide
4. Once the setup is complete, replace the detector's
cover and mount the Walk-Tester under the detector.
The Walk-Tester comes with a mounting bracket
holder (fig.7).
5. Once the Walk-Tester is mounted properly, slightly
loosen the stainless-steel screw on the bottom of the
detector enough to allow for the drilled tab on the
Walk-Tester bracket to slide around the screw thread.
6. Gently tighten the screw to hold the Walk-Tester
bracket in place (fig. 8). Please note that the
Walk-Tester can be moved around the base of the
detector within a 180°, allowing for visibility during
walk testing.
7. Once the Walk-Tester is properly installed and
connected to the detector, turn the Walk-Tester on.
Fig.8 Walk-Tester in holder and fitted
to detectors, ready for walk testing
The Walk-Tester will illuminate and sound an alarm every
time the detector is activated.
8. Once the test is completed, turn the Walk-Tester off and
remove it and the holder from the detector. Tighten the
screw on the base of the detector. See the detector's
manual for more information.
SPECIFICATIONS
POWER
9VDC (PP3 Cell)
CURRENT
Standby: 0.5mA
OPERATING TEMP
-4°F to +131°F (-20°C to +55°C)
PROTECTION
Please note that the Walk-Tester is
not waterproof and should not be
used in wet weather conditions
DIMENSIONS
118 x 47 x 25mm
APPROVALS
The manufacturer declares that the product supplied
is compliant with the provisions of the EMC Directive
89/336/EEC amended 92/31/EEC for Electromagnetic
Compatibility, and the Restriction of Hazardous Substances
Directive (RoHS) 2002/95/EC. A Declaration of Conformity
in accordance with the above directives is held on file with
the manufacturer.
CE MARK
Specifications and pricing are subject to change without notice.
Copyright © Digital Watchdog. All rights reserved.

Advertisement

loading