5. CONNECTIONS
POWER
12V AC/DC
Red/Black:
+12V
Blue/Green:
Ground
A varistor is provided to protect/prevent strike from spikes.
Connect varistor between input wires.
Note: For UL 294 / UL 1034 compliance the door strikes are to be
powered via a UL 294/ UL 603 class 2 power limited output from
a control panel and or power supply. Furthermore, when powered
by AC/DC the units shall use a UL regulated UL 294/ UL 603 power
limited class 2 output rated 12/24V with AC on indicator.
6. OPERATION
How to modify fail-safe to fail-secure or vice versa.
(1). Loosen the screw as per the product diagram below.
(2). Rotate the set plate 180° and slide the plate until it is
properly seated.
(3). Tighten the screw.
6. FACEPLATES
INCLUDED IN PACKAGE
⁄ "
1 ¼"
(16mm)
(32mm)
4 ⁄ "
3 ⁄ "
(104mm)
(85mm)
4 ⁄ "
(123mm)
¾"
(19mm)
ESP1B - ANSI SQUARE
Opening New Doors to
Innovation, Quality and Support!
24V AC/DC
Red:
+24V
Black/Blue:
-
Green:
Ground
⁄ "
1 ¼"
(16mm)
(32mm)
6 ⁄ "
(154mm)
6 ⁄ "
3 ⁄ "
(173mm)
(85mm)
1 ¾"
(44mm)
ESP3B - HOLLOW METAL DOOR
Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
CX-ED1079 Series 'Universal' Electric Strike
Orange
Or
FAIL SAFE
⁄ "
1 ⁄ "
(16mm)
(36mm)
7 ½"
(189mm)
3 ⁄ "
7 ⁄ "
(85mm)
(200mm)
2 ¼"
(57mm)
ESP4B - WOOD DOOR
I NSTALLATI ON INS TRUC TIONS
FOR CUT WIRES
Grey
12V
Red
(+12V)
Black
White
Varistor
Blue
( - )
Green
24V
(+24V)
Red
Black
Varistor
Blue
( - )
Green
Door Status Sensor
(Closed position)
With 'L' Models
White = N/O
Grey = N/C
Orange = COM
CHANGING
FAIL SECURE
ADDITIONAL FACEPLATE
⁄ "
(16mm)
4 ⁄ "
3 ⁄ "
(104mm)
(85mm)
4 ⁄ "
(123mm)
¾"
ESP2B - ANSI ROUND
File: CX-ED1079 Series Manual Eng
.indd R6
Revision: 15/07/2019
Part No.: 40-82B192
1 ¼"
(32mm)
(19mm)
Page 3 of 3