4.

Range of use

This swimming pool filter set is for cleaning of swimming pool water. This device is for the private use and not for industrial
or commercial usage.
5.

Installation

5.1.
General Installation Instructions
During the entire process of installation, the device must not be connected to the electrical
mains.
The pump shall be placed on a dry location with an environmental temperature not exceeding
40 °C and not below 5 °C. The pump and the entire connection system have to be protected
from frost.
Make sure the motor of the pump is sufficiently ventilated by air.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and cause
considerable damage. If required, please use a suitable sealant to make the installation airtight.
When tightening threaded connections, please do not apply excessive force which may cause damage.
When laying the connection pipes, you should make sure that the pump is not exposed to any form of weight, vibration or
tension. Moreover, the connection lines must not contain any kinks or an adverse slope.
Please observe the illustrations, too, which are contained as an attachment at the end of the present operating
instructions. The numeric and other details included in brackets below refer to these illustrations.
Please observe the graphic figures in this manual. The numbers and other indications in brackets refer to the following
graphic figures in this text.
5.2.
Installation of sand filter
1.
Mount the pump to sand filter support by using bolts and nuts. (fig. 1)
2.
Install the drain plug assembly to sand tank as below pictures. (fig. 2)