Panasonic Ramsa WR-DA7 Application Manual page 57

Audio mixer
Hide thumbs Also See for Ramsa WR-DA7:
Table of Contents

Advertisement

MIDI Timepiece A/V Setup
For tandem communication between the two WR-DA7s, establish connections from Port 1 OUT to
Port 2 IN and from Port 2 OUT to Port 1 IN.
To have the two WR-DA7s receive MTC from the DA-98, establish connections from Port 3 OUT to
Port 1 IN and to Port 2 IN.
For MMC control of the DA-98 by the master, establish a connection from Port 1 OUT to Port 3 IN.
Macintosh (for Expansion Software) Setup
The serial ports cannot be used for OMS and FREE MIDI. It is recommended, therefore, that they
be disabled using the computer's extension manager.
Expansion Software Setup
Select [Preference] from the Edit menu and open the dialog box.
Select [General], then set [Number of Console] to [2].
Select [Port Setup], then both [Modem] and [Printer] in the Automation Port area. Also set [Sync
Source] to [WR-DA7 Timecode Input].
When [OK] is pressed in the [Preference] dialog, the expansion software loads the setup data from
the master and slave.
To receive timecode set the [Sync Source] to [WR-DA7 Timecode Input] in the Preference Port
Setup area of the Edit menu. Then, enter a check mark at the [Receive Timecode] in the Real-time
menu.
58

Advertisement

Table of Contents
loading

Table of Contents