BRC setting
To synchronize the BRC with the SMPTE timecode from the video recorder set Locate Reference to
'SMPTE Input' and Clock Source to 'Internal' by selecting the EXT SYNC setting for the BRC. Then,
turn on the EXT SYNC switch.
Select the Fixed Mode when the BRC is used as a clockmaster and if the sampling rate is set at
48kHz. Select the Variable Mode when the sampling rate is set at 44.1kHz. Press the PITCH DOWN
switch to setting -147cent ( '44.1' display).
For MTC setting, select MIDI in the GEN SYNC setting area to 'MTC' and turn on the GEN SYNC
switch.
For SMPTE select SMPTE in the GEN SYNC setting area to '-10dB' and turn on the GEN SYNC
switch.
To obtain a timecode output from the BRC even during FF/REW operation of the ADAT, set the dis-
play to 8: Output Rew/FF SMPTE & MTC to 'ON' in MIDI/UTIL setting of the BRC.
To accomplish MMC operation, there must be coincidence of the MIDI channel between MMC
output from the WR-DA7 and MMC received on the BRC. On the BRC, set the display to 11: MIDI
Device screen by MIDI/UTIL setting. Set the value of 'MIDI channel set for the WR-DA7 - 1.'
Otherwise, setting should be made to 'ALL.'
35
A 'CHANNEL STATUS CRCC ERROR' may be displayed during Digital
recording from the DA7.
This is; however, a message in regards to the sub-code signal, even
with this being displayed proper audio recording and playback
should be performed.