OTC Wireless WiSER2400.IP Technical Manual

802.11 wireless serial solutions
Hide thumbs Also See for WiSER2400.IP:

Advertisement

Quick Links

All manuals and user guides at all-guides.com
TECHNICAL MANUAL
For WiSER2400.IP
WiSER2400.Plus
802.11 Wireless Serial Solutions
http://www.otcwireless.com

Advertisement

Table of Contents
loading

Summary of Contents for OTC Wireless WiSER2400.IP

  • Page 1 All manuals and user guides at all-guides.com TECHNICAL MANUAL For WiSER2400.IP WiSER2400.Plus 802.11 Wireless Serial Solutions http://www.otcwireless.com...
  • Page 2 Other product and company names herein may be trademarks of their respective owners. Copyright © 2001-2005, OTC Wireless, Inc. All rights reserved. Version 2.16 WiSER 2400 Technical Manual Version 2.16 Copyright ©...
  • Page 3: Table Of Contents

    Using the WiSER 2400 Administration Software Overview Password Protection Link Status Configuration Page Encryption Statistics Admin APPENDIX Troubleshooting Limited Warranty Regulatory Compliance WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 3 of 32...
  • Page 4: Introduction

    2dBi antenna. It comes supplied with a 5V DC power adapter. The WiSER2400.Plus provides the same functionalities as the WiSER2400.IP. It has an RS-232 DB-9 connector as well as a mini- Phoenix connector for RS-485/422 interfaces. It accepts 5V DC to 32V DC power supply that has to be provided for separately by the user.
  • Page 5 (WiSER2400.Plus) Serial Data Rate 1200, 2400, 4800, 9600, 14.4K, 19.2K, 38.4K, 57.6K, 115.2K Compact integrated omni-directional-antenna (WiSER2400.IP) Input Power 5VDC for WiSER2400.IP (adapter provided); 5VDC to 32 Reverse-SMA connector antenna attachment VDC for WiSER2400.Plus (to be supplied by user) Current <480mA (max.
  • Page 6 1.1.3 Serial Connections WiSER2400.IP WiSER2400.Plus The WiSER2400.IP has a built-in RJ-45 connector and For RS-232 Connection uses an RJ-45 to DB-9 adapter cable for connecting to the serial port of a PC or a device. Two cables are WiSER2400.Plus has a built-in DB-9 connector for included in the package: RS-232 connection.
  • Page 7 Serial Mode Blinking Secure the WiSER2400 at the desired location with the provided Velcro (for WiSER2400.IP) or DIN Rail mounting kit (for WiSER2400.Plus) once the hardware is setup and works properly with the intended host device or Fig. 3 WiSER2400.IP equipment.
  • Page 8 For 3 & 4: The level up position is without terminator. The level down position is with Ground terminator. Fig. 4 WiSER2400.Plus WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 8 of 32...
  • Page 9: Installation

    PC (where ‘nnnn’ is a number). See the VirCOM Technical Manual for the detail information on using VirCOM. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 9 of 32...
  • Page 10: Wiser Deployment Strategies

    Please refer to Section 3 of this manual as well as the VirCOM Technical Manual for details on configuring the WiSER2400 and the Virtual COM port re-directing software. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 10 of 32...
  • Page 11 All manuals and user guides at all-guides.com Fig. 5 WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 11 of 32...
  • Page 12 PC to control the serial device through the wireless link. Please refer to Section 3 of this manual for details on configuring the WiSER2400. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 12 of 32...
  • Page 13 All manuals and user guides at all-guides.com Fig. 6 WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 13 of 32...
  • Page 14: Using The Wiser2400 In A Point-To-Multiple Point Link

    Please refer to Section 3 of this manual as well as the VirCOM Technical Manual for details on configuring the WiSER2400 and the Virtual COM port re-directing software. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 14 of 32...
  • Page 15 All manuals and user guides at all-guides.com Fig. 7 WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 15 of 32...
  • Page 16 PC to control the serial devices through the wireless link. Please refer to Section 3 of this manual for details on configuring the WiSER2400. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 16 of 32...
  • Page 17 All manuals and user guides at all-guides.com Fig. 8 WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 17 of 32...
  • Page 18: Using The Wiser 2400 Administration Software

    There are five Tabs in the administrative software interface window: Link Status Configuration Encryption Statistics Administration Each will be covered in detail below. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 18 of 32...
  • Page 19 The user then selects from the menu for the unit to be configured or into a Disconnect button. Simply click on the “Disconnect” to terminate the link monitored. between the PC and the WiSER2400. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 19 of 32...
  • Page 20: Password Protection

    The Password Utility is also used to add or change a password for a WiSER2400 unit. Fig. 12 WiSER2400 Password Utility panel NOTE: The default password of WiSER2400 is none. (Leave the field blank). WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 20 of 32...
  • Page 21: Link Status

    RF channel, port status, link quality, and signal strength. Use the Refresh button to retrieve/update the Link Status information. Fig. 13 WiSER2400 administration software Link Status panel WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 21 of 32...
  • Page 22: Configuration Page

    Apply button to save the new settings to the WiSER2400. Fig. 14 WiSER2400 administration software Configuration/Serial Port panel WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 22 of 32...
  • Page 23 Byte. If “Other” is selected, the user can configure a Start Frame Byte of up to six bytes. Default value: none WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 23 of 32...
  • Page 24 Configuration/Serial-IP-Proxy panel Note: The WiSER2400 can only operate in either UDP mode or TCP mode, but not in both modes simultaneously. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 24 of 32...
  • Page 25 RTS Threshold: For setting up the RTS threshold for the wireless packet. Lower value recommended for operation network with potential hidden-nodes problems. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 25 of 32...
  • Page 26 The Peer Host is normally the computer on which the serial device’s application program is run. Fig. 17 WiSER2400 administration software Configuration/Peer Host panel WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 26 of 32...
  • Page 27: Encryption

    Key 1 to Key 4. Click the Apply button to save the encryption key setting. Fig. 18 WiSER2400 administration software Encryption panel WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 27 of 32...
  • Page 28: Statistics

    WiSER2400 before being able to be transmitted out wirelessly, usually due to buffer overflow. Fig. 19 WiSER2400 administration software Statistics panel WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 28 of 32...
  • Page 29: Admin

    OTC Technical Support for assistance. Reboot Unit: Applying this action will cause the WiSER2400 to reboot. Fig. 20 WiSER2400 administration software Admin panel WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 29 of 32...
  • Page 30: Appendix

    MAC address of the destination unit. If this does not work, check the IP address settings. WiSER 2400 Technical Manual Version 2.16 Copyright © 2001-2005, OTC Wireless, Inc. All Rights Reserved Page 30 of 32...
  • Page 31: Limited Warranty

    Within 10 seconds after the WiSER2400 has powered up, use the Connect button in the administrative software to establish a serial link All returns must be authorized by OTC Wireless, Inc. and accompanied by a Return with the WiSER2400 radio Materials Authorization (RMA).
  • Page 32: Regulatory Compliance

    Consult the dealer or an experienced radio/TV technician for help. • Caution: Changes or modifications not expressly approved by OTC Wireless could void the user’s authority to operate the equipment. WiSER 2400 Technical Manual Version 2.16...

This manual is also suitable for:

Wiser2400.plus