1.
Select the Nozzle that matches the size of the IC attach the Nozzle when both the pipe and the Nozzle are cool. Should
either be warm, check to make sure that the temperature control knobs set to1
2.
Loosen the screw on the Nozzle
3.
Attach the Nozzle. Do not force the nozzle or pull on the edge of the Nozzle by pliers. Also, do not re-tighten the screw
too tightly

Operating Instructions:

Plug the power cord into the power supply. After connection, the automatic blowing function will start sending air
1.
through the pipe, but the heating element remains cool
2.
Turn the Power switch on. The power switch may be turned on at any time while the automatic blowing function is
operating. Once the power switch is turned on, the heating element will begin to warm up
3.
Adjust the air flow and temperature control knobs. After adjusting the air flow and temperature control knob, wait for
the temperature to stabilize for a short period of time
Melt the solder. Hold the iron so that the Nozzle is located directly over, but not touching the IC and allow the hot air to
4.
melt the solder. Be careful not to touch the leads of the IC with the Nozzle
5.
Remove the IC. Once the solder has melted, remove the IC by lifting the plier
6.
Turn the power switch off. After the power switch is turned off, an automatic blowing function begins sending cool air
through the pipe in order to cool both the heating element and the handle. So do not disconnect the plug during this
cooling process. In case you don't use the unit for a ling time, disconnect the plug
Remove any remaining solder. After removing the IC, remove remaining solder with a wick or desoldering tool
7.
Note: After turn off the power switch of about 1 minute later, power is automatically shut off.
Features:
• Closed loop control of sensor, accurate and stable temperature, which can
safely desolder the temperature-sensitive components, such as QFP, PLCC,
SOP, BGA and so on Intelligent cooling system, Delay blast after operation,
automatic power off when air temperature is less than 100°C
• Original imported heating element, rapid warming, and long life, and good
wielding safety performance, constant and adjustable temperature
• Original imported air pump, low vibration, noise design, which can make the
workplace quiet
• Anti-Static design to avoid bringing damage to PCB board due to static and
creepage
Specifications:
Input voltage
Maximum power consumption
Air pump
Volume
Temperature
Dimension
‫מיקום באתר: מלחמים וציוד הלחמה / מלחמים ותחנות הלחמה / תחנות הלחמה‬
: 110V / 220V AC optional
: 550W
: Diaphragm
: 23L / min (max)
: 100°C to 480°C
: 224mm (L) × 126mm (W) × 110mm (H)mm
‫דיגיטלית‬
‫אוויר חם‬
560W
2362602
‫יבואן: טלמיר אלקטרוניקה בע"מ‬
TM
:‫תיאור פריט‬
‫תחנת‬
:‫יצרן‬
TENMA
:‫דגם‬
21-10125
:‫מק"ט טלמיר‬

Advertisement

loading

Summary of Contents for Talmir TENMA

  • Page 1: Operating Instructions

    Note: After turn off the power switch of about 1 minute later, power is automatically shut off. ‫דיגיטלית‬ :‫תיאור פריט‬ ‫אוויר חם‬ ‫תחנת‬ 560W :‫יצרן‬ TENMA :‫דגם‬ 21-10125 :‫מק"ט טלמיר‬ 2362602 ‫מיקום באתר: מלחמים וציוד הלחמה / מלחמים ותחנות הלחמה / תחנות הלחמה‬ ‫יבואן: טלמיר אלקטרוניקה בע"מ‬...
  • Page 2 Insert the Handle’s projection into the hole in the pipe ‫דיגיטלית‬ ‫אוויר חם‬ ‫תחנת‬ :‫תיאור פריט‬ 560W :‫יצרן‬ TENMA :‫דגם‬ 21-10125 :‫מק"ט טלמיר‬ 2362602 ‫מיקום באתר: מלחמים וציוד הלחמה / מלחמים ותחנות הלחמה / תחנות הלחמה‬ ‫יבואן: טלמיר אלקטרוניקה בע"מ‬...