McIntosh MPM4000 Owner's Manual
McIntosh MPM4000 Owner's Manual

McIntosh MPM4000 Owner's Manual

Power output meter
Hide thumbs Also See for MPM4000:

Advertisement

All manuals and user guides at all-guides.com
OWNER’S
MANUAL
Power Output Meter
MPM4000
McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, New York 13903-2699 Phone: 607-723-3512 FAX: 607-724-0549

Advertisement

Table of Contents
loading

Summary of Contents for McIntosh MPM4000

  • Page 1 All manuals and user guides at all-guides.com OWNER’S MANUAL Power Output Meter MPM4000 McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, New York 13903-2699 Phone: 607-723-3512 FAX: 607-724-0549...
  • Page 2: Thank You

    We want you to be as familiar as possible with all the features and functions of your new McIntosh MPM4000. This will ensure that you receive all the perfor- mance benefits this equipment can offer you, and that it will become a highly valued part of your Automotive entertain- ment system.
  • Page 3: Customer Service

    All manuals and user guides at all-guides.com Please Take A Moment con’t, Customer Service Purchase Date: Customer Service If at any time you have questions about your MPM4000 Power Output Meter, please contact: McIntosh Laboratory, Inc. Dealer Name: 2 Chambers Street...
  • Page 4: Table Of Contents

    All manuals and user guides at all-guides.com Table of Contents Table of Contents Thank You ................2 Illustration 4 ..............13 Please Take a Moment ............2 How to Connect ............... 14 How to Operate ..............14 Customer Service ............... 3 Table of Contents ...............
  • Page 5: Safety Instructions

    All manuals and user guides at all-guides.com Safety Intructions IMPORTANT SAFETY INSTRUCTIONS! NO USER-SERVICEABLE PARTS INSIDE. REFER PLEASE READ THEM BEFORE SERVICING TO OPERATING THIS EQUIPMENT. QUALIFIED PERSONNEL WARNING SHOCK HAZARD - General: DO NOT OPEN. 1. Read all the safety and operating instructions, contained in this owner’s manual, before operating this equip- AVIS RISQUE DE CHOC - ment.
  • Page 6 All manuals and user guides at all-guides.com Safety Instructions con’t 3. Adhere to all warnings and operating instructions. Connection: 4. Follow all operating and use instructions. 9. Connect this equipment only to the type of DC power 5. Warning: To reduce risk of fire or electrical shock, source as marked on the unit.
  • Page 7 13. Refer servicing to a qualified service personnel under service technician has used replacement parts specified the following conditions: by McIntosh or have the same characteristics as the A. The cords or the connectors have been damaged, original part. Unauthorized substitutions may result in B.
  • Page 8: Introduction

    Amplifier. you with the capability of seeing the actually power output • McIntosh Traditional Analog Meter Display from your McIntosh Power Amplifier even though it is • Wide dynamic range mounted elsewhere in your car. The direct reading wattage •...
  • Page 9: Supplied Items

    All manuals and user guides at all-guides.com Supplied Items Supplied Items Quantity Description Reference No. Main Unit, with Spring Brackets DIN Bracket Bracket L/R M4 x 8 Flat Head Screws M5 x 8 Flat Head Screws M5 x 8 Sems hexagonal Bolts Spacer Cushion Cushions Mounting Strip...
  • Page 10: Installation

    In certain vehicle models, the space between the rear side of the escutcheon and the center panel surface may be too deep Spacer Cushion when the MPM4000 is stalled. In such a case, stick the at- Remove tached spacer cushion to the MPM4000 refer to figure 1.
  • Page 11: Illustration 2

    All manuals and user guides at all-guides.com Illustration 2 If you need to use the trim spacer, please use the following MPM4000 to be mounted together using the same mounting steps: bracket. Refer to figure 2 and the following steps: 1.
  • Page 12: Illustration 3

    Mounting Strip It may be necessary in certain cases to use the brackets sup- plied with vehicle. The following steps apply see (figure 3): 1. Mount the springs to the MPM4000 by using the M5 x 8 flat head screws. Cushion 2.
  • Page 13 All manuals and user guides at all-guides.com Illustration 4 Control Center Supplied Illustration 4 with Cushion Supplied Vehicle Figure 4 below is for mounting the MPM4000 with the sup- Cushion with plied DIN Bracket and Spring clips. Vehicle MPM4000 DIN Bracket Left Bracket...
  • Page 14: How To Connect

    All manuals and user guides at all-guides.com How to Connect and Operate How to Connect How to Operate The MPM4000 active meter circuity allows direct readings of power output from the power amplifier it is connected to. Wire Color Connect to...
  • Page 15: Specifications

    Dimensions 7-3/8 inches (188mm) Wide, 2-1/4 inches (58mm) High, 4- call or write Customer Service Department of McIntosh Laboratory. Please see the Part List for the correct part 1/4 inches (107.4mm) depth numbers.
  • Page 16 All manuals and user guides at all-guides.com McIntosh Laboratory, Inc. 2 Chambers Street Binghamton, NY 13903 McIntosh Part No. 040505...

Table of Contents