SETTING THE CONFIGURATION SWITCHES
To set the configuration switches, remove the back panel which is secured by two screws. Then
slide the cover back to expose the switches. The switches can be changed with power ON and
the new settings will take affect immediately.
SW1-1, SW1-2, SW1-3, & SW1-4
ADDRESS GROUP SELECTION
SW1
SW2
SW3
SW4
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
1024~1280
ON
OFF
ON
OFF
1281~1536
OFF
ON
ON
OFF
1537~1792
ON
ON
ON
OFF
1793~2048
OFF
OFF
OFF
ON
2049~2304
ON
OFF
OFF
ON
2305~2560
OFF
ON
OFF
ON
2561~2816
ON
ON
OFF
ON
2817~3072
OFF
OFF
ON
ON
3073~3328
ON
OFF
ON
ON
3329~3584
OFF
ON
ON
ON
3585~3840
ON
ON
ON
ON
3841~4096
VICON BAUD RATE
ON:
BOSCH
VICON
OFF: 4800 Baud
1~256
1~256
257~512
1~256
513~768
1~256
769~1024
1~256
1~256
1~256
1~256
1~256
1~256
1~256
1~256
1~256
1~256
1~256
1~256
1~256
3
SW1-6
9600 Baud
LTC 8782/xx-01 Ver 4.0