Download Print this page

Tascam RS-232 Specification Sheet page 3

Cassette deck, rs-232 specification

Advertisement

COMMAND LIST (CONT)
RTZ, DECK 1 - CMND "2D"
RTZ, DECK 2
CPS FFWD, DECK 1 - CMND "1D"
CPS REW, DECK 1
CPS FFWD, DECK 2
CPS REW, DECK 2
SENSE MECH STATUS, DECK 1 - CMND "50"
SENSE MECH STATUS, DECK 2
SENSE TAPE STATUS, DECK 1 - CMND "56"
SENSE TAPE STATUS, DECK 2
SENSE TAPE COUNTER, DECK 1 - CMND "5A"
SENSE TAPE COUNTER, DECK 2
TALLY STRUCTURE & BEHAVIOR
Return Tallies:
The first section following the preamble willl define
whether the tally is giving information about
Mechanism Status (D0h), Tape Status (D6h), or
Tape Counter (DAh) tally.
For Mechanism Status tallies, following bits will
represent the current function of a deck, which
mechanism is being described, and the direction the
system is defaulted to. (Side A or Side B)
For Tape Counter tallies, the data blocks will
represent the Mechanism first, then the minutes and
seconds. If the 322 is in CPS mode, the minutes
display will transmit "CP" and the seconds will show
the number of breaks the CPS mechanism is going
to pass. (This is exactly mimicking the timer display
on the 322.)
It should be noted that the 322 will not transmit
positive or negative time information from the deck,
though the display can indicate negative time.
7733 Telegraph Road
All features and specifications are subject to change without notice. Contact your local TASCAM representative for the latest information.
Continued on next page.
Montebello, CA 90640
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
0Ah
30h
LF
0
D
0
0Ah
30h
44h
30h
31h
IN STOP, DECK 1, SIDE A
As with the FFWD and REW transport commands, FFWD and REW
tallies do not reverse for side B. They are always shuttling tape
in the same direction. So, on side B, REW will shuttle ahead, and
FFWD will shuttle back. This is consistant with having a dedicate
PLAY B button, keeping the relational arrows for commands.
LF
0
D
A
0Ah
30h
44h
41h
30h
TAPE COUNTER 2 SHOWS 26:47
(323) 726-0303
http://www.tascam.com
322 RS-232 Specification
2
D
0
1
0
32h
44h
30h
31h
30h
2
D
0
2
0
32h
44h
30h
32h
30h
1
D
0
1
0
31h
44h
30h
31h
30h
1
D
0
1
0
31h
44h
30h
31h
30h
1
D
0
2
0
31h
44h
30h
32h
30h
1
D
0
2
0
31h
44h
30h
32h
30h
5
0
0
1
CR
35h
30h
30h
31h
0Dh
5
0
0
2
CR
35h
30h
30h
32h
0Dh
5
6
0
1
CR
35h
36h
30h
31h
0Dh
5
6
0
2
CR
35h
36h
30h
32h
0Dh
5
A
0
1
CR
35h
41h
30h
31h
0Dh
5
A
0
2
CR
35h
41h
30h
32h
0Dh
1
0
0
1
0
30h
31h
30h
30h
0
2
2
6
4
32h
32h
36h
34h
0
CR
30h
0Dh
0
CR
30h
0Dh
1
CR
31h
0Dh
2
CR
32h
0Dh
1
CR
31h
0Dh
2
CR
32h
0Dh
1
CR
31h
0Dh
7
CR
37h
0Dh