  • Page 1 Model 3701 Line Probe User Manual...
  • Page 2 ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall constitute ETS-Lindgren L.P. assuming any liability whatsoever arising out of the application or use of any product or circuit described herein.
  • Page 3: Table Of Contents

    Table of Contents Notes, Cautions, and Warnings ..........v 1.0 Introduction ................7 ETS-Lindgren Product Information Bulletin ........... 7 2.0 Maintenance ................. 9 Annual Calibration ..................9 Service Procedures ..................9 3.0 Specifications ..............11 Electrical Specifications ................11 Physical Specifications ................11 4.0 Operation ................
  • Page 4 This page intentionally left blank.
  • Page 5: Notes, Cautions, And Warnings

    Notes, Cautions, and Warnings Note: Denotes helpful information intended to provide tips for better use of the product. Caution: Denotes a hazard. Failure to follow instructions could result in minor personal injury and/or property damage. Included text gives proper procedures. Warning: Denotes a hazard.
  • Page 6 This page intentionally left blank.
  • Page 7: Introduction

    1.0 Introduction The ETS-Lindgren Model 3701 Line Probe is a wire clamp-on device that attaches to the AC power mains providing primary power to the equipment under test. When it is not practical to use a Line Impedance Stabilization Network (LISN), the Model 3701 can measure conducted emissions, and may be used to block the power mains frequency while allowing the higher frequencies (9 kHz to 30 MHz) present on the line to be measured.
  • Page 8 This page intentionally left blank.
  • Page 9: Maintenance

    2.0 Maintenance Before performing any maintenance, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. Maintenance of the Model 3701 is limited WARRANTY to external components such as cables or connectors. To prevent electrical shock, do not remove cover.
  • Page 10 This page intentionally left blank.
  • Page 11: Specifications

    3.0 Specifications Electrical Specifications Frequency Range: 9 kHz–30 MHz Maximum AC Voltage: 250 VAC line-to-ground Input Connector: Conductive hook with spring-loaded plastic shroud Output Connector: Type BNC receptacle Installation: Indoor use only Altitude: 4572 m maximum 15000 ft maximum Physical Specifications Length: 216 mm 8.5 in...
  • Page 12 This page intentionally left blank.
  • Page 13: Operation

    4.0 Operation Before connecting any components, follow the safety information in the ETS-Lindgren Product Information Bulletin included with your shipment. To avoid electrical shock, do not make contact with the power mains conductor when power is applied through the conductor. When attaching the Model 3701 Line Probe, always remove power.
  • Page 14 This page intentionally left blank.
  • Page 15: Appendix A: Warranty

    Appendix A: Warranty See the Product Information Bulletin included with your shipment for the complete ETS-Lindgren warranty for your Model 3701. 3701 URATION OF ARRANTIES FOR ODEL All product warranties, except the warranty of title, and all remedies for warranty failures are limited to two years.