11 Service Diagnosis

11.1 Caution for Diagnosis
The operation lamp flashes when any of the following errors is detected.
1. When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions,
disabling equipment operation.
2. When a signal transmission error occurs between the indoor and outdoor units. In either case, conduct the
diagnostic procedure described in the following pages.
11.2 Parameter of primary electronic appliance
N
O
N
a
m
e
1
Compressor
2
Fan motor
3
Reactor
4
4-way valve
P
a
a r
m
t e
r e
Rated voltage:220 V
Rated current:3.3A
Rated frequency:50 Hz
Resistance 1.41Ω
Rated voltage: 310V
Rated current:0.2A
Rated frequency:50/60Hz
Rated power:40W
Rated voltage:16.56V±5%
Rated current:10.5A
Rated frequency:50Hz
Rated inductance:5.0mH±5%
Rated voltage:220-240V
Rated frequency:50/60Hz
Power :4.5/3.5W
P
c i
u t
e r
46
Service diagnosis