Installation

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
 Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
 Isolate the unit before starting any work.
 Secure the unit to prevent unintentional switching on.
Screw T distributor to the connection socket, screw nozzle tube to the T distributor (A1). Screw nozzle mounting and
the desired water feature nozzle to the nozzle tube (A2). It is possible to connect a hose to the lateral outlet at the T
distributor by means of the reduction element and the stepped hose connection (A3). Place the unit in the pond hori-
zontally on firm, sludge-free ground and ensure that it is completely covered with water (at a maximum of 2 m below
the water level).
Align the nozzle tube. The water feature height and the water flow can be adjusted with a regulator at the lateral outlet
at the T distributor (B). The power supply must be disconnected to switch off the unit.
Set-up the unit
Note!
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear
and will require earlier replacement.
Remedy:
 Thoroughly clean the pond or pool before installing the pump.
 Install the pump approx. 200 mm above the floor of the pond to avoid excessively soiled water from being
drawn into the pump.
 Install the unit in the pond in a horizontal position on firm, sludge-free ground and ensure that it is completely cov-
ered with water.
Start-up
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Attention! The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump
automatically switches on again once the motor has cooled down. Risk of accident!
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
 Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
 Isolate the unit before starting any work.
 Secure the unit to prevent unintentional switching on.