Decoding laser scanner
Table of Contents

Advertisement

All manuals and user guides at all-guides.com
Codabar Selection, continued
Check Character
Validate, But Don't Transmit
Concatenation
Codabar supports symbol concatenation. When you Allow concatenation, the
reader will look for a Codabar symbol having a D" start character, adjacent to
a symbol having a D" stop character. In this case the two messages are
concatenated into one with the D" characters omitted.
Character:
Codabar
Select Require to prevent the reader from decoding a lone Codabar symbol.
Don't Allow (Concatenation Off)
Allow
Programming Tip: If a symbology will not be used, we recommend turning
it off to minimize the chance of a misreads and to increase the snappiness of
the scanner.
1551C Decoding Laser Scanner User's Guide
No Check Character
Validate, And Transmit
Start
Stop Start
Stop
A12D
D34A
Concatenation
Require
4–3

Advertisement