Philips 32PFL3606H/12 Service Manual page 25

Tpm6.1e chassis
Hide thumbs Also See for 32PFL3606H/12:
Table of Contents

Advertisement

5.8.4
Unstable Picture via HDMI input
Check (via ComPair) if HDMI EDID data is properly
programmed.
5.8.5
No Picture via HDMI input
Check if HDCP key is valid. This can be done in CSM.
5.8.6
TV Will Not Start-up from Stand-by
Possible Stand-by Controller failure. Reflash the SW.
5.8.7
Audio Amplifier
The Class D-IC U6006 has a power pad for cooling. When the
IC is replaced it must be ensured that the power pad is very well
pushed to the PWB while the solder is still liquid. This is needed
to insure that the cooling is guaranteed, otherwise the Class
D-IC could break down in short time.
5.8.8
CSM
When CSM is activated and there is a USB memory stick
connected to the TV, the software will dump the complete CSM
content to the USB memory stick. The file (Csm.txt) will be
saved in the root of the USB memory stick.
5.8.9
Loudspeakers
Make sure that the volume is set to minimum during
disconnecting the speakers in the ON-state of the TV. The
audio amplifier can be damaged by disconnecting the speakers
during ON-state of the set!
5.8.10 Display option code
Attention: In case the SSB is replaced, always check the Panel
Code in CSM, even when picture is available. Performance
with the incorrect display option code can lead to unwanted
side-effects for certain conditions.
Service Modes, Error Codes, and Fault Finding
back to
div. table
TPM6.1E LA
5.
EN 25
2011-Jun-10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents