For best performance, allow a 2" (5 cm) space around the side and the top. Do not put any objects on top of the chiller that could
obstruct the fan.
8
6
4

Location Requirements

4
9
5
7
10
8.72"
(22.14 cm)
3
2
1
14.75"
5
(37.46 cm)
10.
(26.16 cm)

Electrical Requirements

A 120-volt, 60-Hz, 15- or 20-amp, grounded electrical supply is required.
This drinking water cooler is intended to be connected to a ground fault
circuit interrupting (GFCI) device to meet UL requirements.
It is recommended that a separate circuit serving only your chiller unit
be provided. Use an outlet that cannot be turned on/off by a switch.
Recommended Ground Method
The chiller must be grounded. This appliance is equipped with a power
supply cord with a 3 prong ground plug. To minimize possible shock
hazard, the cord must be plugged into a mating, 3 prong, ground-type
outlet, grounded in accordance with all national and local codes and
ordinances. If a mating outlet is not available, it is the personal
responsibility and obligation of the customer to have a properly
grounded, 3 prong outlet installed by a qualified electrician.
1. Chiller unit
2 . Blue tubing included
with chiller
3 . Faucet is required
(sold separately)
4 . Cold water supply line
5 . White tubing included
with chiller
6. Filtration
(sold separately)
7. Water supply fitting
(sold separately)
8. Filter inlet
9. Filter outlet
10 . Quick connect fitting
included with chiller