Wiring Centre Description
1. Serial Connector
2. Power Supply
3. Connection diode
Introduction
The KL04RF module is an extension to the KL08RF wiring centre for an additional 4 heating zones. Works
only in combination with KL08RF wiring centre and increases its functionality up to 12 individual heating
zones.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following
EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, Radio directive 2014/53/EU
and RoHS directive 2011/65/EU. The full text of the EU Declaration of Conformity is available at the
following internet address: www.saluslegal.com
Safety Informations
Use in accordance with national and EU regulations. Device is intended for indoor use only in dry
conditions. Product for indoor use only. Installation must be carried out by a qualified person in
accordance to national and EU regulations.
Before attempting to setup and install, make sure that KL04RF is not connected to any power source.
Installation must be carried out by a qualified person. Incorrect installation may cause damage to the
wiring centre. The KL04RF should not be installed in areas where it may be exposed to water or damp
conditions.
Technical Information
Power Supply
230 V AC
Max load
3 A
Outputs
Thermoelectric actuator 230V AC
Dimensions [mm]
163 x 85 x 67
4. Power supply diode
5. Work status indication of each zone
6. Output terminals for actuators
2
3
4
5
1
9
10
KL04RF
1. Serial connector
It is used for communication between KL08RF wiring centre and KL04RF extension module. Combined
set increases support up to 12 zones.
2. Power supply
230 V AC
L
N
11
12
6
9
10
11
12
Power supply for wiring centre is 230V ~, 50Hz.
Features of the installation:
• two-wire, with PE protective conductor,
• made in accordance with applicable regulations.
9
10
11
12

Advertisement

loading

Summary of Contents for Salus KL04RF

  • Page 1 Before attempting to setup and install, make sure that KL04RF is not connected to any power source. Installation must be carried out by a qualified person. Incorrect installation may cause damage to the wiring centre. The KL04RF should not be installed in areas where it may be exposed to water or damp 2. Power supply conditions.
  • Page 2 KL04NSB 4. Power supply diode After connecting the KL04RF module to the power supply, Power led diode will light solid red. KL04NSB 5. Work status indication of each zone Green led diode lights up when the heating demand signal is being transmitted from the thermostat to the given zone (with NC actuators connected).