Salus KL04RF Manual
Salus KL04RF Manual

Salus KL04RF Manual

Wiring centre extension for kl08rf

Advertisement

Wiring centre extension for KL08RF
Model: KL04RF
Manual
DISTRIBUTOR OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4,
43-262 Kobielice,
Poland
Importer:
SALUS Controls plc
Salus House, Dodworth Business Park
Whinby Road, Barnsley S75 3SP,
United Kingdom
www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right
to change specification, design and materials of products listed in this brochure without prior notice.

Wiring Centre Description

1. Serial Connector
2. Power Supply
3. Connection diode

Introduction

The KL04RF module is an extension to the KL08RF wiring centre for an additional 4 heating zones. Works
only in combination with KL08RF wiring centre and increases its functionality up to 12 individual heating
zones.

Product Compliance

This product complies with the essential requirements and other relevant provisions of the following
EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, Radio directive 2014/53/EU
and RoHS directive 2011/65/EU. The full text of the EU Declaration of Conformity is available at the
following internet address: www.saluslegal.com

Safety Informations

Use in accordance with national and EU regulations. Device is intended for indoor use only in dry
conditions. Product for indoor use only. Installation must be carried out by a qualified person in
accordance to national and EU regulations.
Before attempting to setup and install, make sure that KL04RF is not connected to any power source.
Installation must be carried out by a qualified person. Incorrect installation may cause damage to the
wiring centre. The KL04RF should not be installed in areas where it may be exposed to water or damp
conditions.

Technical Information

Power Supply
230 V AC
Max load
3 A
Outputs
Thermoelectric actuator 230V AC
Dimensions [mm]
163 x 85 x 67
4. Power supply diode
5. Work status indication of each zone
2
3
4
5
1
9
10
KL04RF
1. Serial connector
It is used for communication between KL08RF wiring centre and KL04RF extension module. Combined
set increases support up to 12 zones.
2. Power supply
230 V AC
L
N
11
12
6
9
10
11
12
Power supply for wiring centre is 230V ~, 50Hz.
Features of the installation:
• two-wire, with PE protective conductor,
• made in accordance with applicable regulations.
9
10
11
12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KL04RF and is the answer not in the manual?

Questions and answers

Summary of Contents for Salus KL04RF

  • Page 1 Before attempting to setup and install, make sure that KL04RF is not connected to any power source. Installation must be carried out by a qualified person. Incorrect installation may cause damage to the wiring centre. The KL04RF should not be installed in areas where it may be exposed to water or damp 2. Power supply conditions.
  • Page 2 KL04NSB 4. Power supply diode After connecting the KL04RF module to the power supply, Power led diode will light solid red. KL04NSB 5. Work status indication of each zone Green led diode lights up when the heating demand signal is being transmitted from the thermostat to the given zone (with NC actuators connected).

Table of Contents