Bosch GAL Professional 3860 CV Original Instructions Manual page 10

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
10 | English
Charger
Standard batteries: Charging
time at battery capacity, approx.
– 1.3 Ah
– 1.5 Ah
– 2.0 Ah
– 2.6 Ah
– 3.0 Ah
– 4.0 Ah
– 5.0 Ah
– 6.0 Ah
Number of battery cells
Weight according to EPTA-Pro-
cedure 01:2014
Protection class
A)
not valid for article number 2 607 225 929
Operation
Start-up
Note the mains voltage! The voltage of the power source
u
must match the voltage specified on the rating plate of
the charger. Chargers marked with 230 V can also be op-
erated with 220 V.
Charging process
The charging process begins as soon as the mains plug for
the charger is inserted into the mains socket and the battery
(1) is inserted into the charging slot (4).
Thanks to the intelligent charging process, the charge condi-
tion of the battery is automatically detected and then
charged up with the optimal charge current depending on
battery temperature and voltage.
In this way, the battery is treated with care and remains per-
manently fully charged when it is stored in the charger.
What the display elements mean
Flashing green battery charge level indicator (2)
The rapid-charging procedure is indicated by
flashing of the green battery charge level in-
dicator (2). The battery can be removed at any
time and used.
Note: The charging process is only possible when the tem-
perature of the battery is within the permitted charging tem-
perature range, see section "Technical data".
Once approx. 80% of the battery capacity has
been reached, the flashing of the green battery
80 %
charge indicator slows down. The rapid-char-
ging process is now completed. If the battery
remains in the charger, the charging process
will be completed in the Long Life charging mode.
1 609 92A 4Z5 | (08.05.2019)
GAL 3680 CV
80%/100%
min
min
min
min
min
min
min
min
kg
Continuously illuminated green battery charge level
indicator (2)
The battery can then be removed for immediate use.
When there is no battery connected, the continuous light of
the battery charge level indicator (2) indicates that the
mains plug is plugged into the mains socket and that the
charger is ready to be used.
Continuously illuminated red battery charge level
indicator (3)
data". The charging process begins as soon as the permitted
temperature range has been reached.
Flashing red battery charge level indicator (3)
ive measures".
Indications on 36 V Batteries
During the charging procedure, the three green charge-con-
trol indicators (5) of the battery light up one after the other
and briefly go out. The battery is fully charged when the
three green indicators light up continuously. After approx.
5 minutes after the battery has been fully charged, the three
green indicators go out again.
When the red temperature control indicator (6) lights up
when placing the battery into the charger, the temperature
of the battery is not within the charge-temperature range
(see section "Technical Data"). The battery cannot be
charged until after the allowable operating temperature
range has been reached.
GAL 1880 CV
10/25
10/25
15/30
15/30
20/35
25/35
35/45
35/55
4–30
0.82
/ II
The continuous light of the green battery
charge level indicator (2) signals that the bat-
tery is fully charged.
The continuous light of the red battery charge
level indicator (3) shows that the temperature
of the battery is outside of the permitted char-
ging temperature range, see section "Technical
The flashing light of the red battery charge
level indicator (3) signals that the charging
process has been interrupted by a different
fault, see section "Errors – causes and correct-
Bosch Power Tools
80%/100%
10/25
10/25
15/30
15/30
20/35
25/35
35/45
35/55
4–10
0.66
A)
/ II

Hide quick links: