Download Print this page

Hamilton Air HA1000 Adjustment Instructions

Standard overhead teller door adjustment instructions

Advertisement

Quick Links

3143 Production Drive Fairfeild, Ohio 45014 513-874-3733
HA1000 and HA45
Standard Overhead Teller
Door Adjustment Instructions
Doc #08-319
Est. 4/7/11
Revision 1
1

Advertisement

loading

Summary of Contents for Hamilton Air HA1000

  • Page 1 3143 Production Drive Fairfeild, Ohio 45014 513-874-3733 HA1000 and HA45 Standard Overhead Teller Door Adjustment Instructions Doc #08-319 Est. 4/7/11 Revision 1...
  • Page 2 Teller Door Adjustment Instructions 1) Remove two H3580 hex head screws from B6545 lower cover. 2) Remove B6545 lower cover. 3) Remove two H0673 phillips truss screws from B6546 upper cover. 4) Remove B6546 cover to access two more H3580 screws. H0673 Phillips Truss B6546 Upper Cover B6545 Lower Cover...
  • Page 3 Teller Door Adjustment Instructions 5) Loosen H3581 spring plunger so that the door closes without contacting the H3581 spring plunger. 6) Loosen H3580 hex head screws that are holding B6562 detent mounting block and slide the B6562 detent mounting block to the maximum left side of its slot. 7) Retighten the H3580 hex head screws to hold the B6562 detent mounting block in place.