I N S T A L L A T I O N
Must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and
1
regulations by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply
with the following installation instructions will void the warranty and may result in serious injury or possible death. Ensure power
is off before installation, verify electrical plan first and read all installation instructions prior to installation. With the constant
development of our products please check our website (www.modalight.com) for any possible changes to the installation of this
product.
Debe ser instalado por un electricista calificado de acuerdo con todos los códigos y reglamentos eléctricos y de construcción nacionales y locales, por una
persona familiarizada con la construcción y el funcionamiento del producto y los riesgos involucrados. El incumplimiento de las siguientes instrucciones de
instalación anulará la garantía y puede provocar lesiones graves o la muerte. Asegúrese de que la energía esté apagada antes de la instalación, verifique
primero el plan eléctrico y lea todas las instrucciones de instalación antes de instalar. Con el constante desarrollo de nuestros productos, visite nuestro website
(www.modalight.com) para todos posibles cambios en la instalación de este producto.
Doit être installé par un électricien qualifié conformément à tous les codes et réglementations électriques et de construction nationaux et locaux par une
personne connaissant bien la construction et le fonctionnement du produit et les risques encourus. Le non-respect des instructions d'installation suivantes
annulera la garantie et pourrait entraîner des blessures graves ou la mort éventuelle. Assurez-vous que l'alimentation est coupée avant l'installation, vérifiez
d'abord le plan électrique et lisez toutes les instructions d'installation avant l'installation. Avec le développement constant de nos produits s'il vous plaît consulter
notre site web (www.modalight.com) pour toutes les modifications possibles à l'installation de ce produit.
Verify electrical plan and ensure all hardware is present
2
Verificar plan electrico y verifique que todo el equipo esté presente
Vérifier le plan électrique et assurer que tout le matériel est présent
Dimmer
Moda Bridge
Leader
(Optional)
(Optional)
Cable
Mounting Bracket
(Bottom View)
7/32" (5.25mm)
1/8"
(3.5mm)
2 11/16" (68.25mm)
3 5/32" (80mm)
Due to continuous improvements and innovations, specifications may change without notice.
Please refer to our website for current technical data. These figures are provided as a guideline
only and may vary with differing power supplies and installations. All rights reserved. E&OE.
DRY/DAMP LOCATION INSTALL
INSTALACIÓN DE LUGARES SECOS/HÚMEDOS
INSTALLATION EMPLACEMENT SEC/HUMIDE
Jumper Cable
Max Continuous Run: See section 15
Continuidad Máxima: Vea sección 15
Run continue Max: Voir la section 15
1 7/32"
1 1/2"
(31mm)
(38mm)
Mounting Bracket can be moved to the left or right of the fixture
El soporte se puede mover hacia la izquierda o hacia la derecha del accesorio
Le support de montage peut être déplacé vers la gauche ou la droite de l'appareil
M O DA M I N I C OV E
!
1 1/2" (38 MM)
!
I N T E R I O R E LV
®
Fixture to
Fixture
Connection
Overall fixture length
with connectors:
6in - 6 27/32" (174.18mm)
1ft - 1' 15/32" (317.10mm)
4ft - 4' 1/2" (1.23m)
8ft - 8' 1/2" (2.45m)
VDC 09/13/2019
955 White Drive Las Vegas, NV 89119 | T: 702 407 7775
F: 702 407 7773 | www.modalight.com | © 2019
Terminator
1 / 12

Advertisement

loading
Need help?

Need help?

Do you have a question about the Moda Mini Cove Interior ELV and is the answer not in the manual?

Questions and answers

Summary of Contents for Moda Light Moda Mini Cove Interior ELV

  • Page 1 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N Must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations by a person familiar with the construction and operation of the product and the hazards involved.
  • Page 2 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N Mount to surface using the 4 screw holes on the bracket Monte a superficie utilizando los 4 agujeros para tornillos en el soporte Mont à...
  • Page 3 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N Snap Moda Mini Cove Interior into mounting track then slide to connect fixtures Encaje Moda Mini Cove Interior en el canal de montaje y luego deslice para conectar accesorios Accrochez Moda Mini Cove Interior dans la piste puis faites glisser pour connecter les appareils Minimum end to end spacing is 9/64”...
  • Page 4 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N Wiring Moda Bridge (Optional) Cablería Moda Bridge (Opcional) Cables Moda Bridge (Optionnel) 0-10V Dimmer...
  • Page 5 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N Connect leader cable and connect terminator CLICK! Connectar el cable leader y conectar Terminador Branchez le câble leader et connectez Terminateur Ensure a positive click to avoid arcing...
  • Page 6 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N Attach optional louvre to the top of the fixture until it clicks into place. Use four of these louvres for four foot fixtures. Coloque la lumbrera opcional en la parte superior del dispositivo hasta que encaje en su lugar.
  • Page 7 Allumer! Maximum continuous run Longitud máxima continua Longueur maximale continue PRODUCT 120V AC 240V AC 277V AC Moda Mini Cove Interior ELV SO 6in 120ft 240ft 240ft Moda Mini Cove Interior ELV SO 1ft 120ft 240ft 240ft Moda Mini Cove Interior ELV SO 4ft...
  • Page 8 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N Compatible dimmers Atenuadores de luz compatibles Gradateurs compatibles INPUT VOLTAGE: 120V AC, 60Hz OUTPUT VOLTAGE: 41.5V (at non-dimming) OUTPUT CURRENT: 95mA (at...
  • Page 9 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N INPUT VOLTAGE: 120V AC, 60Hz OUTPUT VOLTAGE: 41.5V (at non-dimming) OUTPUT CURRENT: 95mA (at non-dimming) Output...
  • Page 10 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N FIXTURE Moda Mini Cove Interior Standard Output Silver ELV Dimming 1800K HCRI 6IN 090-0001 Moda Mini Cove Interior Standard Output Silver ELV Dimming 2200K HCRI 6IN 090-0003...
  • Page 11 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N ACCESSORIES DESCRIPTION Leader Cable US 3 Pin 10ft Power to first fixture of run 299-0000 Leader Cable US 3 Pin 25ft...
  • Page 12 M O DA M I N I C OV E I N T E R I O R E LV ® I N S T A L L A T I O N Do not attempt to install or use the product Do not mix SO fixtures with HO fixtures.