Download Print this page

Siemens SAK 51 Installation Instructions page 2

Advertisement

Fig. 4
Fig. 5
Fig. 6
4. Wiring
4.1 E-Bus (fig. 4)
The E-Bus (B4+,B3,B2,B1-) must be connected to the
central control panel (A) and also to other accessories (B).
For additional information see the Control panel installation
manual
4.2 Audio for SAK 52 (fig. 5)
Connect terminals A- and A+ to the central control unit (E) (e.g.
WMA 11), and also to other accessories (D).
Connect terminals 1 and 2 to the speaker (C).
A twisted pair with a minimum diameter of 0.6 mm must be
used to avoid extraneous noise. The length of the audio link
to the central control unit must not exceed 200 m.
5. Close and seal the housing (fig. 6)
1 - Engage the cover in the top retainer (A).
2 - Close the cover (B).
6. Start-up
6.1 Microphone sensitivity
The sensitivity of the microphone can be set using the
connector (fig. 3 item E). Connector closed = max. sensitivity,
connector open = min. sensitivity.
6.2 Speaker volume
The volume of the speaker can be set using the connector
(fig. 3 item R). Connector closed = max. volume, connector
open = min. volume.
6.3 Addressing
To enter an address in the remote keypad, simultaneously press
keys
and
and hold for approximately 5 sec.
6.4 Display address
To display the current address of the remote keypad,
simultaneously press keys
6.5 Test of displays
Simultaneously press keys
and the buzzer.
7. Technical data
Supply (12
)
V
DC
Power consumption min.
Power consumption max.
Operating temperature
Housing
Dimensions in mm
Safety class
Environmental
Weight
The right to make technical changes to the described equipment without prior notice
is reserved - © 2002 -
and
.
and
to activate all LEDs
From the E-Bus
22,5 mA
105 mA
0° C to +55° C
ABS
H 110 x W 170 x D 32
IP 30
class II
250 g