Advertisement

Quick Links

AIM-DAC System
DAC844
User Manual
1
Anviz Global Inc

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DAC844 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Anviz DAC844

  • Page 1 AIM-DAC System DAC844 User Manual Anviz Global Inc...
  • Page 2 The use of the software associated with the system and/or product, if applicable, is subject to the terms of the license provided as part of the purchase documents. Anviz global.Inc and/or its related companies and/or subsidiaries’ (hereafter: "Anviz") exclusive warranty and liability is limited to the warranty and liability statement provided in an appendix at the end of this document.
  • Page 3: Table Of Contents

    2.1.2 RS485 Communication ..................... 8 2.2 Product Interface ......................... 9 2.3 Product Wiring ........................10 2.3.1 DAC844 Earth Wiring ....................10 2.3.2 Reader, Switch and Door Contact Wiring ............... 10 2.3.3 Lock connection ..................... 11 2.3.4 RS485 Wiring ......................11 2.3.4 LED .........................
  • Page 4 AIM-DAC System 1 Product Introduce DAC844 is a simple and flexible access controller. It is based on TCP/IP communication. The device adopts the latest PCB process design to make sure the working stable and reliable, meet the different needs of the market.
  • Page 5: Product Feature

    AIM-DAC System 1.1 Product feature DAC844 is a powerful and suitable for a wide range of access control solutions. 4 standard Wiegand 26 input for 4 doors  4 relays output directly control 4 locks (Maximum Current <5A)  TCP/IP network communication , RS485 communication (Baud Rate:115200bps) ...
  • Page 6: Product Parameters

    12V -4A Standby:86mA Max:560mA Max/Min Working Current 4 Switching Signals,4 door contacts Input 4 relays 12V 5A (NO NC COM) Relay LED prompt 22 LEDs TCP/IP, RS485(115200bps) Communication -10℃—50℃ Working Temperature Working Humidity 0-80% Size 128*128*15mm (H*W*D) Weight Anviz Global Inc...
  • Page 7: Product Operation

    AIM-DAC System 2 Product Operation 2.1 Product Communication 2.1.1 Net Work Communication wiring Communication Mode TCP/IP Anviz Global Inc...
  • Page 8: Rs485 Communication

    AIM-DAC System 2.1.2 RS485 Communication Communication mode RS485 Anviz Global Inc...
  • Page 9: Product Interface

    Describe Power Input 4 Switching Signal Input Min USB port (Upgrade firmware) 4 Door Contact Input TCP/IP port 4 Relay Output (NO,NC,COM) RS485 port (A+,B-,GND) 4 Readers Input I2C Expand Port() Restart Button Fire Alarm input Earth Anviz Global Inc...
  • Page 10: Product Wiring

    AIM-DAC System 2.3 Product Wiring Please follow below steps wiring with DAC844: Please make sure the DAC844 connect with Earth. Connect with Reader, Switch and Door Contact equipment Connect with Lock RS485 communication LED prompts 2.3.1 DAC844 Earth Wiring Earth Reader, Switch and Door Contact Wiring 2.3.2...
  • Page 11: Lock Connection

    AIM-DAC System Remark: Exit Button means Switch Door Sensor means Door Contact Reader, Switch and Door Contact Lock connection 2.3.3 Lock and Relay RS485 Wiring 2.3.4 RS485 Wiring Anviz Global Inc...
  • Page 12: Led

    Door Contact prompt LEDs (Y) ② Relays prompt LEDs (G) ③ Reader Wiegand 26 input prompt LEDs (G) ④ RS485 Communication prompt LEDs (Left: Y Right: G) ⑤ Fire Alarm Input (G) ⑥ Power (G) ⑦ WatchDog (G) ⑧ Anviz Global Inc...
  • Page 13: Dac System Overview

    1. Enter a Use Name and type a Password. By default, the User Name is "admin" and Password is “1”. Note: 2. Click “Confirm” The main DAC window opens. The SW versions in the screenshots are exemplary. Note: Anviz Global Inc...
  • Page 14: Starting The Software

    The AIM DAC System Main window has three Parts: Section Description Controls the software general operation and device setup. Controls register User information in the System. Monitoring all the access, alarms and error events. Click “ ” back to AIM DAC System Main windows. Anviz Global Inc...
  • Page 15: Device Management

    3.3.1 Controller Operation Controller option has two parts. Part One: Edit: Add and edit the DAC844 device information into the software. Controller S/N: After added the controller in the software, the administrator could select controller via the controller ID. Search: Click “Search” option into Quick Add Device interface.
  • Page 16 TCP/IP mode: Please enter the “Controller No.”. The “Controller NO.” is the unique ID of the DAC844. You can find it in the DAC844 Package or on the DAC844 product lable. It is a 6 digit number. Such as ”44893”.
  • Page 17 RS485 mode Please enter the “Controller No.”. The “Controller NO.” is the unique of the DAC844. You can find it in the DAC844 Package or on the DAC844 product lable. It is a 6 digit number. Such as ”44893”. Select “COM” in “Connection Mode” and Select Com Port number in the drop down list。...
  • Page 18 At the left side of the “Setting” interface display the selected DAC844 device’s information; include “Controller No.”, “Connection Mode” and Device status. “Status”: controls each relay and relay status on the DAC844. (The DAC844 have 4 relays output.) “Door Open Delay”: controls the relay working delay time. (3000 means 3000ms. The minimum delay time is 100ms.
  • Page 19 C-D: Reader C and Reader D two readers make up an Anti-Passback application. A-B C-D: Four Readers make up two areas Anti-Passback application. Please click “Setup” upload all the settings in the DAC844 device. Interlock: Enable door Interlock to prevent two doors from opening at the same time. It should only be possible to open one door at a time with a valid user code.
  • Page 20 Password: Controls all of PIN Pad operation. Include enable PIN Pad, Super Password, Card+Password functions. Enable PIN Pad: Enable PIN Pad function the DAC844 device will support the KEY pad reader and number input from the KEY pad. And the Duress Password function can be used.
  • Page 21 Note: MAC Address is unique for each DAC844 device. Please click “Setup” save and upload all the settings in the DAC844 device. Clear: To clear the settings in the DAC844 device. Please select the settings which you want to clear.
  • Page 22: Door Operation

    There are two parts in Door Edit interface, include “All the Door” and “Controller Door”. All the Door: Listed out all of doors in each controller. Controller Door: list out selected DAC844 controller’s door. The administrator could edit door information via select controller.
  • Page 23 AIM-DAC System Add: add a door for controller and door information. Note: Because different DAC device support different doors. Such as DAC844 maximum support 4 doors. By default the software list out all of doors for a controller. So you do not need add doors when you first time to use software.
  • Page 24 Delete: Delete the door group. Select the door group in the “Door Group List”, click “Delete” to delete. Modify: Modify the door group information. Select the door group in the “Door Group List”, click “Modify” to edit door group information. Anviz Global Inc...
  • Page 25: Time Zone

    Start / Ending Date: Date range of the time zone. The date range can be week, month and year. The format is: YYYY-MM-DD. Link Time: is a time zone for subsequent event after current time zone. Such as setup “link Anviz Global Inc...
  • Page 26 “Upload” to upload the time zone to selected controller. The system will pop up a window to prompt succeed or failed. For Example: Access control for normal working time. Start working time is 9:00—18:00 1 Select a Time Zone No 2 I nput a Time Zone Name Anviz Global Inc...
  • Page 27 So we just need use 1st Time Zone Start—1st Time Zone End that’s enough. And the time range of the 1st Time Zone we had best more loose time range (Some body will early in office and later out office) 6 Upload the Time Zone to controller Anviz Global Inc...
  • Page 28: Privilege

    AIM-DAC System Please click “Add” and select the controller in the controller. Click “Upload” to upload time zone to DAC844 device. 3.3.4 Privilege Privilege option: It is according to the rules of time zone, authorized the user privilege to pass the door or not allowed to pass the door.
  • Page 29 “ put all of doors or door groups to right side. Click “ “ put select single door or door group to right side. The selected doors and door groups will list in right side of the “Door / Door Group area”. Anviz Global Inc...
  • Page 30 Add Time Zone area: Time Zone No: Please select time zone in the drop down box. Name: Display Time Zone name. Start Date / End Date: This date range is the privilege expiry date. It is different with time zone. Anviz Global Inc...
  • Page 31 ” button the user authorized pass the door. Click” ” button the user cannot pass the door. Note: After authorized the user pass the door. The “Ban Pass the door” function uses to cancel user pass door privilege. Anviz Global Inc...
  • Page 32 After “operation Successful!”, The user access control privilege has made up and store in the system database. Now we need upload these access control privilege to the corresponding DAC844 devices. In the “Upload” interface, please select corresponding DAC844 controller in the Controller list. Click “ ” to upload Access control privileges to the Controller.
  • Page 33: First Card

    Controller List and select a door in Edit column. First Card Time: It is time point. The first card must be verified at this time point the door will change the status. Anviz Global Inc...
  • Page 34 “ put single user to right side. The selected users will list in right side of the “User area”. Click “ “ to put all users back to left side. Click “ “ to put single user back to left side. Anviz Global Inc...
  • Page 35 In the Upload interface, click first card information. You could check the firs card members in the right list. Note: You can back to Edit interface to Modify or Delete first card information. Click “Upload” to upload first card information to controller. Anviz Global Inc...
  • Page 36 AIM-DAC System Anviz Global Inc...
  • Page 37: Multi Card

    The Multi Card function also controls a single door. So administrator needs select a controller in the Controller List and select a door in Edit column. After selected the door, click “Add” and “Continue Operation” will pop up below window: Anviz Global Inc...
  • Page 38 200. Multi Card Group: There are 8 groups. The Group can make multi card function more agile. Click “ ” or “ “to assign user to different groups. For example: There are 4 groups with different users. Anviz Global Inc...
  • Page 39 Click “Delete” to delete “Multi Card” setting in the AIM-DAC system database. After modified the “Multi Card” setting in the AIM-DAC system, please click “Modify” to save the settings. Note: To clear the “Multi Card” functions in the controller. Please refer to 3.3.1 Controller Operation – Clear. Anviz Global Inc...
  • Page 40: Crontab

    Execution Time: Setting a time point. Status Control:Door change status when at execution time. Door: Select a door will have crontab function. The DAC844 normal with 4 doors. Select a conntroller in the conntroller list and Click “Add” will make up crontab informations store in the system database and click “Upload”...
  • Page 41: Access Records

    This interface include two parts: “Extract recrods” and “Browse”. The “Extract records” interface could download the access records from controller. Select All: Download all records from all of controllers. The “Browse” interface could select records according the condition setting in the software. Anviz Global Inc...
  • Page 42: User Management

    “User list”. Also could select the user in the “User list”, modify the user information in the “Base Info.”, to click “Modify” button to save or click “Delete” to delete selected user. Anviz Global Inc...
  • Page 43 Controll ID: Please select the Controll ID in the drop down list and click “Select” to active “Qucik Add” function. Then administrator could swipe the card on any readers which connect with the DAC844 device. Then in the below list will display all the card numbers. When you finsih swipe cards.
  • Page 44 Name and Serial No in the “Base Info.” area. Register Fingerprint The AIM-DAC system support Anviz T5 fingerprint reader. So the system provided the user’s fingerprint in the DAC844 access controller. Step 1 Input “No”, ”Name” and “Password” in the “Base Info” area. Except the “Card No”...
  • Page 45 System. And we could use this number to the user (who we register in the Step 1). Then the user with fingerprint registered in AIM-DAC System. Note: The number from the T5 is the Wiegand 26 code for user fingerprint. Anviz Global Inc...
  • Page 46: Real Time Monitoring

    After register the User please refer to the section 3.3.4 Privilege to authorized user. 3.5 Real Time Monitoring Enable the Real Time Monitoring function; the AIM-DAC System could display any operation in the system monitoring windows. Click “Monitoring” button will enable the Real Time Monitoring function. Anviz Global Inc...
  • Page 47 Stop: Click “Stop” to stop monitoring the controller. Map: AIM-DAC system support import image. The administrator could import the building floor maps into the system. So could put the door icon on the maps to monitoring. The image support BMP and JPGE. Anviz Global Inc...
  • Page 48 In the Real Time Monitoring windows, we can also support multiple records. Such as: Exit button open the door. Swipe the card to open the door. And the abnormity warning also display in the software. The abnormity warning will display in the right side of the Real Time Monitoring windows. Anviz Global Inc...
  • Page 49: Initialization The Access Controller

    There is an initialization button in the access controller. The user could hold press the initialization button for 4-5 sec. and the reader prompt LEDs will flash 8-9 times. After initialization the controller all the user information will not be clearly. Only the IP address back to default IP address: 192.168.0.150 Anviz Global Inc...
  • Page 50: Upgrade Firmware For Dac844

    AIM-DAC System 5 Upgrade Firmware for DAC844 The DAC844 could upgrade the firmware via the Mini USB port. When you need upgrade the firmware please hold press initialization button and power on the DAC844. The DAC844 device wills only bright Power LED.

Table of Contents