Operating manual HANDcure Translation of the original operating instructions This operating manual must be kept permanently at hand at the location of the IST device and ® must be read carefully by the operating staff. www.ist-uv.com/handcure Further language versions on:...
EC Declaration of Conformity EC/EU DECLARATION OF CONFORMITY The manufacturer IST METZ GmbH Lauterstraße 14-18 D-72622 Nürtingen hereby declares that the design of: Device type: HANDcure ® from batch no.: 62114172 complies with the following European directives and harmonized standards.
Page 4
Information. This symbol indicates key information on use. Non-observance can lead to failure. Page number Warranty The manufacturer‘s warranty expires in case of improper Warranty operation and improper use, as well as unauthorized modifications to the HANDcure or components supplied by IST METZ GmbH 12/18 HANDcure...
1.1 UV light Danger The UV light emitted by the HANDcure presents risks. Never look into the light source, as this can cause permanent damage to the eyes. Never point the light source directly at people or animals.
Safety 1.3 Improper use Product misuse The HANDcure is used in curing and detection by means of long-wave UVA light. This includes the cross-linking of UV adhesives, the cross-linking of UV-cured sealing compounds and resins and the detection and inspection of material properties and particle contamination.
+25 °C. If the product is brought from a cold room into a warm one, condensation may form. Stationary operation It is possible to fix the HANDcure in a bracket or jig using two threads at the sides. If this is necessary for reasons of application technology, the device must be securely fixed in position and screened.
Warning of UV radiation Exposure can lead to irritation of the eyes or skin. Ordinary individuals are forbidden to use it. Use suitable screens. According to EN 62471, the HANDcure was classified in Risk Group 3. Safety gear required It is essential to avoid visual contact with the illuminated LED.
Start up 3 START UP Display with control panel Front screen Attachment thread (on both sides) OFF/ON -Switch Battery pack Fastening for wrist strap Up/Down arrow keys oK key 02/18 HANDcure HANDcure...
0 1 : 2 8 B a t : [ 8 1 % ] T e m p : 2 4 ° C Switching off: Exposure can be interrupted at any time using the On/Off switch. 02/18 HANDcure HANDcure...
Check the front screen for dirt before using the device and, if required, clean it with a lint-free cloth and alcohol. Take out the battery pack of the HANDcure before cleaning Do not clean the device using aggressive cleaning agents.
Technical Data of the IST Unit ® 4 TECHNICAL DATA 4.1 HANDcure Operating voltage: 15 ─ 18 VDC Power consumption: 30 W Spectral range (standard): 365 ─ 415 nm Spectral range (option): 395 nm Spectral range (option): 385 nm Angle of aperture: ~ 90°...